TriWaSp: a multi-faceted visible spectroscopy diagnostic on the ST40 tokamak
Journal Article
·
· Journal of Instrumentation
- Tokamak Energy Ltd. (United Kingdom)
- Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Here, we present a new state-of-the-art Triple Wavelength Spectrometer (TriWaSp), recently deployed on ST40, a high field low aspect ratio spherical tokamak. The TriWaSp has a range of possible applications due to its flexible design; the current configuration focuses on charge exchange recombination spectroscopy from carbon and neon impurities in the ST40 plasma. This paper discusses the detailed setup of the system and presents initial charge exchange ion temperature measurements using a single line of sight, which show good agreement with other ion temperature diagnostics. Building on these commissioning results and forward modelling of the system, a new observation geometry has been implemented for the next experimental campaign which will considerably improve the localisation of ion temperature and velocity profile measurements.
- Research Organization:
- Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
- Sponsoring Organization:
- USDOE
- Contributing Organization:
- Princeton Plasma Physics Laboratory (PPPL)
- Grant/Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1986203
- Journal Information:
- Journal of Instrumentation, Journal Name: Journal of Instrumentation Journal Issue: 03 Vol. 18; ISSN 1748-0221
- Publisher:
- Institute of Physics (IOP)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Overview and status of construction of ST40
|
journal | November 2017 |
Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM
|
journal | August 2020 |
Achievement of ion temperatures in excess of 100 million degrees Kelvin in the compact high-field spherical tokamak ST40
|
journal | March 2023 |
Similar Records
Characterisation of ion temperature and toroidal rotation on the ST40 tokamak
Design and commissioning of resistive foil bolometer diagnostics on the ST40 tokamak
Journal Article
·
Sun Mar 19 20:00:00 EDT 2023
· Journal of Instrumentation
·
OSTI ID:1985348
Design and commissioning of resistive foil bolometer diagnostics on the ST40 tokamak
Journal Article
·
Sun Aug 18 20:00:00 EDT 2024
· Review of Scientific Instruments
·
OSTI ID:2447289