Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Overview of the Water-Based RIA Testing in TREAT

Conference ·
OSTI ID:1969090
We have completed a series of reactivity-initiated accident commissioning tests with the static water capsule in the Transient Reactor Test Facility. The test campaign included a calibration test followed by five tests in the Static Environment Rodlet Transient Test Apparatus capsule. The conditions varied from room temperature and pressure up to 200°C and 2.5 MPa, with energy depositions varying between ~500–1100 J/gUO2. The series of tests allowed for a number of instrumentation qualifications and demonstrations, including cladding thermometry, rodlet plenum pressure, cladding elongation, and an electro-impedance boiling detector. This paper documents the design of the capsule and highlights the results from the commissioning tests.
Research Organization:
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1969090
Report Number(s):
INL/CON-21-62748-Rev000
Country of Publication:
United States
Language:
English

Similar Records

Overview of the Water-Based RIA Testing in TREAT
Conference · Sun Oct 24 00:00:00 EDT 2021 · OSTI ID:1969089

Water-based Ria Testing in TREAT: Commissioning and Early Results
Technical Report · Thu Sep 30 00:00:00 EDT 2021 · OSTI ID:2458198

Resumption of water capsule reactivity-initiated accident testing at TREAT
Journal Article · Thu Aug 03 20:00:00 EDT 2023 · Nuclear Engineering and Design · OSTI ID:1995995