Determination of iron, chromium and nickel by x-ray fluorescence aqueous solution method
- Atomics International, Canoga Park, CA (United States)
The iron, chromium, and nickel content in many types of stainless steels were determined by X-ray fluorescence. The steel samples were dissolved in aqua regia and hydrofluoric acids,fumed with perchloric acid and diluted to volume with water. The fluorescence data were obtained for specific K alpha lines and the intensities were compared to the background intensity reading obtained at 0.6 A, and the values obtained from a standard plot.
- Research Organization:
- Atomics International, Canoga Park, CA (United States)
- Sponsoring Organization:
- US Atomic Energy Commission (AEC)
- DOE Contract Number:
- AT(11-1)-GEN-8
- OSTI ID:
- 1962079
- Report Number(s):
- NAA-SR--1788
- Country of Publication:
- United States
- Language:
- English
Similar Records
DETERMINATION OF IRON, CHROMIUM, AND NICKEL BY FLUORESCENT X-RAY ANALYSIS. AQUEOUS SOLUTION METHOD
A STUDY OF EQUILIBRIA INVOLVED BETWEEN DAREX OFF-GASES AND SOLUTIONS. Final Technical Report. Project No. A-427
Chromium in aqueous nitrate plutonium process streams: Corrosion of 316 stainless steel and chromium speciation
Journal Article
·
Mon Jun 01 00:00:00 EDT 1959
· Analytical Chemistry (U.S.) Formerly Ind. Eng. Chem., Anal. Ed.
·
OSTI ID:4246572
A STUDY OF EQUILIBRIA INVOLVED BETWEEN DAREX OFF-GASES AND SOLUTIONS. Final Technical Report. Project No. A-427
Technical Report
·
Sun Jul 31 00:00:00 EDT 1960
·
OSTI ID:4093060
Chromium in aqueous nitrate plutonium process streams: Corrosion of 316 stainless steel and chromium speciation
Journal Article
·
Sat Dec 30 23:00:00 EST 1995
· Waste Management
·
OSTI ID:367874