A laboratory facility for irradiation at elevated temperatures

Technical Report ·
DOI:https://doi.org/10.2172/1962075· OSTI ID:1962075
 [1];  [1];  [1]
  1. Atomics International, Canoga Park, CA (United States)

A laboratory irradiation facility has been designed and built using 2000 curies of cobalt-60 inside a 3-ton movable dome. Relatively large volumes can be irradiated with highly uniform dose rate distributions. Radiation levels are reroducibley adjustable from 104 to 2.5 x 106 r/hr. The source was designed to permit irradiations at temperatures up to 450 C. Since the average external radiation level is less than 0.1 mr/hr, the facility can be used in a laboratory equipped with radiation measuring equipment and continuous access by personnel.

Research Organization:
Atomics International, Canoga Park, CA (United States)
Sponsoring Organization:
US Atomic Energy Commission (AEC)
DOE Contract Number:
AT(11-1)-GEN-8
OSTI ID:
1962075
Report Number(s):
NAA-SR--1704
Country of Publication:
United States
Language:
English

Similar Records

Design of the second radiation laboratory and results of dose rate measurement
Journal Article · Fri Jul 15 00:00:00 EDT 1960 · Tokyo Kogyo Shikensho Hokoku · OSTI ID:4135188

DESIGN OF A Co$sup 60$ IRRADIATION FACILITY
Technical Report · Wed Feb 28 23:00:00 EST 1962 · OSTI ID:4818246

Activation of electrical machinery. Supplement 1. [Preliminary evaluation; not applicable to ground tests]