Magnetic moment of Be(9)
Technical Report
·
OSTI ID:195178
The ratio of the frequency of the nuclear magnetic resonance of Be(9) to that of the proton has been measured at 7000 gauss by the magnetic-resonance-absorption method of Pound, Purcell, and Torrey. The magnet and radiofrequency bridges employed were those used by both Bitter and Poss in their recent nuclear-magnetic-moment determinations. However, the accuracy of the present measurement exceeds that of previous measurements with this equipment by about a factor of ten. This was accomplished by taking advantage of the almost integral ratio of the two frequencies and heterodyning the seventh harmonic of the Be(9) frequency with the fundamental of the proton frequency.
- Research Organization:
- Massachusetts Inst. of Tech., Cambridge, MA (United States). Research Lab. of Electronics
- OSTI ID:
- 195178
- Report Number(s):
- AD-A--298576/0/XAB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nuclear moments of /sup 9/Li
A NUCLEAR MAGNETIC RESONANCE SPECTROMETER (thesis). Technical Report No. 1
MAGNETIC MOMENT OF THE TRITON IN UNITS OF THE MAGNETIC MOMENT OF THE PROTON
Journal Article
·
Mon Aug 01 00:00:00 EDT 1983
· Phys. Rev. C; (United States)
·
OSTI ID:5603072
A NUCLEAR MAGNETIC RESONANCE SPECTROMETER (thesis). Technical Report No. 1
Technical Report
·
Fri May 01 00:00:00 EDT 1959
·
OSTI ID:4211615
MAGNETIC MOMENT OF THE TRITON IN UNITS OF THE MAGNETIC MOMENT OF THE PROTON
Journal Article
·
Sat Aug 15 00:00:00 EDT 1959
· Physical Review (U.S.) Superseded in part by Phys. Rev. A, Phys. Rev. B: Solid State, Phys. Rev. C, and Phys. Rev. D
·
OSTI ID:4216767