Title: Experimental heat transfer and friction in channels roughened with angled, V-shaped, and discrete ribs on two opposite walls

Journal Article · · Journal of Turbomachinery
DOI:https://doi.org/10.1115/1.2836602· OSTI ID:194215
;  [1];  [2]
  1. Northeastern Univ., Boston, MA (United States). Dept. of Mechanical Engineering
  2. General Electric Corp., Lynn, MA (United States)

Experimental investigations have shown that the enhancement in heat transfer coefficients for air flow in a channel roughened with angled ribs is on the average higher than that roughened with 90 deg ribs of the same geometry. Secondary flows generated by the angled ribs are believed to be responsible for these higher heat transfer coefficients. In an effort basically to double the area of high heat transfer coefficients, the angled rib is broken at the center to form a V-shaped rib, and tests are conducted to investigate the resulting heat transfer coefficients and friction factors. Three different square rib geometries, corresponding to blockage ratios of 0.083, 0.125, and 0.167, with a fixed pitch-to-height ratio of 10, mounted on two opposite walls of a square channel in a staggered configuration, are tested in a stationary channel for 5,000 < Re < 30,000. Heat transfer coefficients, friction factors, and thermal performances are compared with those of 90 deg, 45 deg, and discrete angled ribs. The V-shaped ribs are tested for both pointing upstream and downstream of the main flow. Test results show that: (a) 90 deg ribs represent the lowest thermal performance, based on the same pumping power, and is essentially the same for the 2:1 change in blockage ratio, (b) low-blockage-ratio (E/D{sub h} = 0.083) V-shaped ribs pointing downstream produced the highest heat transfer enhancement and friction factors. Among all other geometries with blockage ratios of 0.125 and 0.167, 45 deg ribs showed the highest heat transfer enhancements with friction factors less than those of V-shaped ribs, (c) thermal performance of 45 deg ribs and the lowest blockage discrete ribs are among the highest of the geometries tested in this investigation, and (d) discrete angled ribs, although inferior to 45 deg and V-shaped ribs, produce much higher heat transfer coefficients and lower friction factors compared to 90 deg ribs.

Sponsoring Organization:
USDOE
OSTI ID:
194215
Report Number(s):
CONF-940626-; ISSN 0889-504X; TRN: IM9611%%56
Journal Information:
Journal of Turbomachinery, Vol. 118, Issue 1; Conference: 39. international gas turbine and aeroengine congress and exposition, The Hague (Netherlands), 13-16 Jun 1994; Other Information: PBD: Jan 1996
Country of Publication:
United States
Language:
English