Condition monitoring and testing for operability of check valves and pumps
Conference
·
OSTI ID:192519
A detailed analysis of historical failure data available through the Institute of Nuclear Power Operations` Nuclear Plant Reliability Data System (NPRDS) has been conducted for both check valves and pumps. This analysis, which originated as a part of the Nuclear Regulatory Commission`s (NRC) effort to evaluate the effects of age and wear on nuclear systems components, involved the manual review and characterization of several thousand component failure records according to parameters inherent in the NPRDS database and supplemented by those defined by the analyst for each component type. For example, failure information relative to component size, age, system of service, and NSSS vendor was readily available from the NPRDS database and could be compared relatively easily. Determination of parameters such as extent of degradation, affected area, and detection method, however, had to be determined based on manual review and characterization of individual failure narratives. This paper discusses some of the results of the analyses of historical check valve failure data from 1984 through 1992 and pump failure data from 1990 through 1993. A comparison of the findings of the analyses is made, and emphasis is placed on evaluation of the effectiveness of certain failure detection methods for each component type. Generally speaking, while it was observed that check valve degradation or failure was likely to be detected by code or regulatory required testing, it was discovered that pump degradation or failure was most likely to be discovered by voluntarily implemented plant programs. Failure rates were found to be strongly influenced by the valve or pump application. The type of plant (BWR or PWR) was the overall failure rate and the method of failure detection.
- Research Organization:
- Oak Ridge National Lab., TN (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States); Nuclear Regulatory Commission, Washington, DC (United States)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 192519
- Report Number(s):
- CONF-9510156--8; ON: DE96005451; CNN: Contract No. 1886-8632-4W
- Country of Publication:
- United States
- Language:
- English
Similar Records
Failure Modes and Causes for Swing and Lift Type Check Valves.
Review and analysis of check valve failure data
Review and analysis of check valve failure data
Conference
·
Tue Dec 30 23:00:00 EST 1997
·
OSTI ID:621557
Review and analysis of check valve failure data
Conference
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:5347299
Review and analysis of check valve failure data
Conference
·
Mon Jun 01 00:00:00 EDT 1992
·
OSTI ID:10150447