Field Study of Grid-connected Heat Pump Water Heaters in the Southeast U.S.: The Next Right Thing
Conference
·
OSTI ID:1922474
- BATTELLE (PACIFIC NW LAB)
- UNIVERSITY OF CENTRAL FLORIDA
- University of Central Florida
The integration of grid-connected functionality and advanced control algorithms into heat pump water heaters (HPWH) offers the capability to shift load with minimal customer impact. This capability provides a flexible grid resource to utilities, while the increased energy efficiency of HPWHs offers customers a lower electric bill. The combined utility/customer value from grid-connected HPWHs is compelling in the Southeast U.S. where residential electric water heating is prevalent and utility load management is common. This paper presents the results of a HPWH load shifting study conducted in Central Florida using the CTA-2045 standard. Building upon previous research in the Pacific Northwest, this study consisted of approximately 45 occupied homes equipped with HPWHs undergoing load shifting strategies weekly for over a year. Curtailment durations ranged from three to five hours in the morning, and four to five hours in the evening to coincide with high-value periods for utility coincident load for system-wide electric demand reductions. During the morning and afternoon, a one- or two-hour load-up event preceded curtailment. Baseline data were collected across varied Florida weather in which no load shifting events were implemented. Results from traditional load shifting strategies were analyzed across seasons and used to devise unique load shifting approaches to increase renewable energy use during periods of high solar energy generation. Regional impacts are forecasted for large-scale implementation of strategies. Lessons learned and recommendations are also provided for how utilities, manufacturers, and regional planners can maximize load shifting benefits from grid-connected HPWHs.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 1922474
- Report Number(s):
- PNNL-SA-171512
- Country of Publication:
- United States
- Language:
- English
Similar Records
Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters
Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.
Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters
Conference
·
Tue Aug 23 00:00:00 EDT 2022
·
OSTI ID:1922478
Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.
Conference
·
Fri Aug 09 00:00:00 EDT 2024
·
OSTI ID:2453912
Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters
Conference
·
Wed Sep 01 00:00:00 EDT 2021
·
OSTI ID:1922486