Detection of high energy muons with sub-20 ps timing resolution using L(Y)SO crystals and SiPM readout
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- European Organization for Nuclear Research (CERN), Geneva (Switzerland)
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Precise timing capability will be a key aspect of particle detectors at future high energy colliders, as the time information can help in the reconstruction of physics events at the high collision rate expected there. Other than being used in detectors for PET, fast scintillating crystals coupled to compact Silicon Photomultipliers (SiPMs) constitute a versatile system that can be exploited to realize an ad-hoc timing device to be hosted in a larger high energy physics detector. In this paper, we present the timing performance of LYSO:Ce and LSO:Ce codoped 0.4% Ca crystals coupled to SiPMs, as measured with 150 GeV muons at the CERN SPS H2 extraction line. Small crystals, with lengths ranging from 5 mm up to 30 mm and transverse size of 2×2mm2 or 3×3mm2, were exposed to a 150 GeV muon beam. SiPMs from two different companies (Hamamatsu and FBK) were used to detect the light produced in the crystals. The best coincidence time resolution value of (14.5±0.5)ps , corresponding to a single-detector time resolution of about 10 ps, is demonstrated for 5 mm long LSO:Ce,Ca crystals coupled to FBK SiPMs, when time walk corrections are applied.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- European Research Council (ERC); USDOE Office of Science (SC), High Energy Physics (HEP)
- Grant/Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1906074
- Report Number(s):
- FERMILAB-PUB-16-787-SCD; oai:inspirehep.net:1467081
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 830; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Effect of Mg 2+ ions co-doping on timing performance and radiation tolerance of Cerium doped Gd 3 Al 2 Ga 3 O 12 crystals
|
journal | April 2016 |
Test beam studies of the light yield, time and coordinate resolutions of scintillator strips with WLS fibers and SiPM readout
|
journal | March 2017 |
Development of the CMS MIP timing detector
|
journal | April 2020 |
| Precision Timing with the CMS MIP detector | preprint | January 2018 |
Similar Records
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET
Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal
Journal Article
·
Wed Jul 14 20:00:00 EDT 2021
· JINST
·
OSTI ID:1830380
Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET
Journal Article
·
Sun Sep 25 20:00:00 EDT 2022
· Physics in Medicine and Biology
·
OSTI ID:2470717
Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal
Journal Article
·
Mon Mar 25 20:00:00 EDT 2024
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:2369561