Validation of MCNP4a for highly enriched uranium using the Battelle process safety and risk management IBM RS/6000 workstation
This document has been prepared to allow use of the Radiation Shielding and Information Center (RSIC) release of MCNP4a, which has been installed on the Battelle Process Safety and Risk Management (PSRM) IBM RS/6000 workstation, for production calculations for the Portsmouth Gaseous Diffusion Plant (PORTS). This hardware/software configuration is under the configuration control plan listed in Reference 1. The first portion of this document outlines basic information with regard to validation of MCNP4a using the supplied cross sections and the additional MCNPDAT cross sections. A basic discussion of MCNP is provided, along with discussions of the validation database in general. A description of the statistical analysis then follows. The results of this validation indicate that the software and data libraries examined may be used with confidence for criticality calculations at the Portsmouth Gaseous Diffusion Plant (PORTS). When the validation results are treated as a single group, there is a 95% confidence that 99.9% of future calculations of similar critical systems will have a calculated k{sub eff} > 0.95. Based on this result, the Battelle PSRM Nuclear Safety Group has adopted the calculational acceptance criteria that a calculated k{sub eff} + 2{sigma}, {le} 0.95 is safely subcritical. The conclusion of this document is that MCNP4a and all associated cross section libraries installed on the PSRM IBM RS/6000 are acceptable for use in performing production criticality safety calculations for the Portsmouth Gaseous Diffusion Plant.
- Research Organization:
- Battelle, Columbus, OH (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
- DOE Contract Number:
- AC05-84OT21400
- OSTI ID:
- 188622
- Report Number(s):
- POEF-SH--33; ON: DE96005116
- Country of Publication:
- United States
- Language:
- English
Similar Records
Validation of MCNP4a for highly enriched uranium using the ports NCS IBM RS/6000 workstation
Configuration control plan for the ports NCS IBM RS/6000
Validation of Nuclear Criticality Safety Software and 27 energy group ENDF/B-IV cross sections
Technical Report
·
Sat Jun 01 00:00:00 EDT 1996
·
OSTI ID:266898
Configuration control plan for the ports NCS IBM RS/6000
Technical Report
·
Sun Jun 30 20:00:00 EDT 1996
·
OSTI ID:273014
Validation of Nuclear Criticality Safety Software and 27 energy group ENDF/B-IV cross sections
Technical Report
·
Mon Aug 01 00:00:00 EDT 1994
·
OSTI ID:10190509