skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Transformative Building Envelope Retrofit Using Insulation-Inflatable Walls Assisted by Automation

Technical Report ·
DOI:https://doi.org/10.2172/1883939· OSTI ID:1883939

This work highlights the effort to develop a low-cost envelope retrofit for homes built prior to the implementation of energy conservation measures established by the Department of Energy. Inflatable structures were constructed to conform to the exterior envelope (a corner wall construction with a fenestration was used as a prototype). The structures were then filled with spray polyurethane foam insulation. The flexibility in construction and the ability to fill with spray polyurethane foam insulation were demonstrated. In addition, hygrothermal simulations showed that the installation of these systems does not compromise the moisture durability of uninsulated and insulated building envelopes across eight climate zones from hot humid to subarctic. Preliminary cost estimates, based on retail pricing, of the inflatable retrofit including 3 inches of spray foam insulation (insulation value of approximately R 20) is $$\$$ 4.25$ per square foot uninstalled. The installed cost was calculated using two labor rates, the labor rate for the installation of a weather resistive barrier and the installation of spray foam insulation. Aggregating those values into one labor rate results in an installed cost between $$\$$ 11$ and $$\$$ 28$ per square foot. The low end includes the installation of vinyl siding as the exterior cladding. The higher value includes an exterior stucco finish.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1883939
Report Number(s):
ORNL/TM-2021/2371
Country of Publication:
United States
Language:
English

Similar Records

Stand-Off Furring in Deep Energy Retrofits, Syracuse, New York (Fact Sheet)
Technical Report · Thu May 01 00:00:00 EDT 2014 · OSTI ID:1883939

Spray Foam Exterior Insulation with Stand-Off Furring
Technical Report · Sat Mar 01 00:00:00 EST 2014 · OSTI ID:1883939

Spray Foam Exterior Insulation with Stand-Off Furring
Technical Report · Sat Mar 01 00:00:00 EST 2014 · OSTI ID:1883939