Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems: Preprint
Conference
·
OSTI ID:1876015
Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. In this paper, a holistic impulse-based MOV lifetime estimation framework is proposed. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.
- Research Organization:
- National Renewable Energy Laboratory (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Solar Energy Technologies Office (EE-4S)
- DOE Contract Number:
- AC36-08GO28308;
- OSTI ID:
- 1876015
- Report Number(s):
- NREL/CP-5D00-82874; MainId:83647; UUID:55e11f85-150b-4ff6-a9bd-1c488cdebfc8; MainAdminID:64824
- Conference Information:
- Presented at the 2022 IEEE 13th International Symposium Power Electronics for Distributed Generation Systems (PEDG), 26-29 June 2022, Kiel, Germany
- Country of Publication:
- United States
- Language:
- English
Similar Records
Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems
Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems
Overvoltage protection of shunt-capacitor banks using MOV arresters
Conference
·
Sun Jun 26 00:00:00 EDT 2022
· 2022 IEEE 13th International Symposium on Power Electronics for Distributed Generation Systems (PEDG)
·
OSTI ID:1898537
Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems
Conference
·
Tue Oct 25 00:00:00 EDT 2022
·
OSTI ID:1909415
Overvoltage protection of shunt-capacitor banks using MOV arresters
Journal Article
·
Wed Aug 01 00:00:00 EDT 1984
· IEEE Trans. Power Appar. Syst.; (United States)
·
OSTI ID:6063738