Recovery sequences for a station blackout accident at the Grand Gulf Nuclear Station
Journal Article
·
· Transactions of the American Nuclear Society
OSTI ID:186600
- Martin Marietta Energy Systems, Oak Ridge, TN (United States)
Recovery sequences for a low-pressure, short term, station blackout severe accident at the Grand Gulf power plant have been investigated using the computer code MELCOR, version 1.8.3 PN. This paper investigates the effect of reflood timing and mass flow rate on accident recovery.
- OSTI ID:
- 186600
- Report Number(s):
- CONF-950601--
- Journal Information:
- Transactions of the American Nuclear Society, Journal Name: Transactions of the American Nuclear Society Vol. 72; ISSN 0003-018X; ISSN TANSAO
- Country of Publication:
- United States
- Language:
- English
Similar Records
Severe accident sequences simulated at the Grand Gulf Nuclear Station
Comparison of MELCOR modeling techniques and effects of vessel water injection on a low-pressure, short-term, station blackout at the Grand Gulf Nuclear Station
MELCOR calculations for a low-pressure short-term station blackout in a BWR-6
Journal Article
·
Wed Sep 01 00:00:00 EDT 1999
· Transactions of the American Nuclear Society
·
OSTI ID:678147
Comparison of MELCOR modeling techniques and effects of vessel water injection on a low-pressure, short-term, station blackout at the Grand Gulf Nuclear Station
Technical Report
·
Thu Jun 01 00:00:00 EDT 1995
·
OSTI ID:90692
MELCOR calculations for a low-pressure short-term station blackout in a BWR-6
Journal Article
·
Sat Dec 30 23:00:00 EST 1995
· Transactions of the American Nuclear Society
·
OSTI ID:186614