Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants: 2020 Update
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Schroeder, Inc., Island Park, ID (United States)
This report documents the quantitative results of the current industry-average performance for components and initiating events (IEs) at U.S. commercial nuclear power plants (NPPs). It represents the third update of the original analysis in NUREG/CR-6928 with data through 2020. Continuous characterization and updating of current industry-average performance with the latest industry data available are important steps in maintaining up-to-date risk models. Typically, data from 1998–2002 were used in NUREG/CR-6928, data from 1998–2010 in the first update, data from 1998–2015 in the second update, and data from 2006–2020 in this update, although many IEs required longer periods for adequate characterization of frequencies in all these analyses. As with NUREG/CR-6928 and previous updates, four types of events are covered in this report: component unreliability (e.g., a pump that fails to start or fails to run), component or train unavailability resulting from test or maintenance outages, special event probabilities covering operational issues (e.g., pump restarts and injection valve re-openings during unplanned demands), and IE frequencies. Results (in the form of beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models covering U.S. commercial NPPs.
- Research Organization:
- Idaho National Laboratory (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- US Nuclear Regulatory Commission (USNRC); USDOE Office of Nuclear Energy (NE)
- DOE Contract Number:
- AC07-05ID14517
- OSTI ID:
- 1847110
- Report Number(s):
- INL/EXT-21-65055-Rev000
- Country of Publication:
- United States
- Language:
- English
Similar Records
Detailed Study of Emergency Diesel Generator Performance Using EPIX/RADS Database
CCF Parameter Estimations, 2020 Update
Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020
Conference
·
Mon Sep 01 00:00:00 EDT 2008
·
OSTI ID:940063
CCF Parameter Estimations, 2020 Update
Technical Report
·
Mon Nov 01 00:00:00 EDT 2021
·
OSTI ID:1846976
Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020
Technical Report
·
Mon Feb 28 23:00:00 EST 2022
·
OSTI ID:1894880