Title: Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Journal Article · · Journal of Building Engineering
 [1];  [1];  [2]
  1. Chongqing Univ. (China). Joint International Research Laboratory of Green Buildings and Built Environments; Chongqing Univ. (China). National Centre for International Research of Low-carbon and Green Buildings
  2. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

Research Organization:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office; Natural Natural Science Foundation of China; U.S.-China Clean Energy Research Center for Building Energy Efficiency Program
Grant/Contract Number:
AC02-05CH11231; 51978095
OSTI ID:
1844366
Alternate ID(s):
OSTI ID: 1763790
Journal Information:
Journal of Building Engineering, Vol. 32; ISSN 2352-7102
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (52)

A modified method of evaluating the impact of air humidity on human acceptable air temperatures in hot-humid environments journal January 2018
Evaluation and improvement of human heat tolerance in built environments: A review journal November 2019
Performance of low-cost indoor air quality monitors for PM2.5 and PM10 from residential sources journal March 2020
An assessment of indoor environmental quality in schools and its association with health and performance journal November 2015
Effects of noise type, noise intensity, and illumination intensity on reading performance journal May 2017
Exploring the “black box” of thermal adaptation using information entropy journal December 2018
Potential Exposure and Cancer Risk from Formaldehyde Emissions from Installed Chinese Manufactured Laminate Flooring: Potential Exposure and Cancer Risk from Formaldehyde Emissions journal November 2017
Occupant satisfaction in LEED and non-LEED certified buildings journal October 2013
Investigation on the Indoor Environment Quality of health care facilities in China journal August 2018
Satisfaction of occupants toward indoor environment quality of certified green office buildings in Taiwan journal February 2014
Validation of continuous particle monitors for personal, indoor, and outdoor exposures journal May 2010
Influence of atmospheric fine particulate matter (PM 2.5 ) pollution on indoor environment during winter in Beijing journal May 2015
A study on the effects of thermal, luminous, and acoustic environments on indoor environmental comfort in offices journal March 2012
Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms journal March 2012
A method to weight three categories of adaptive thermal comfort journal April 2012
Literature survey on how different factors influence human comfort in indoor environments journal April 2011
Investigation of Indoor Air Quality in Primary School Classrooms journal January 2015
Impact of indoor environmental quality on occupant well-being and comfort: A review of the literature journal June 2016
Investigation of the PM2.5, NO2 and O3 I/O ratios for office and school microenvironments. journal December 2019
Chamber Assessment of Formaldehyde and VOC Emissions from Wood-Based Panels journal September 1999
A comparative field study of indoor environmental quality in two types of open-plan offices: Open-plan administrative offices and open-plan research offices journal January 2019
Investigation of Microclimate and Air Pollution in the Classrooms of a Primary School in Wuhan journal January 2015
Machine learning and statistical models for predicting indoor air quality journal July 2019
Indoor/outdoor relationships and diurnal/nocturnal variations in water-soluble ion and PAH concentrations in the atmospheric PM2.5 of a business office area in Jinan, a heavily polluted city in China journal February 2015
A review of standards and guidelines set by international bodies for the parameters of indoor air quality journal September 2015
Spatial variability of indoor air pollutants in schools. A multilevel approach journal December 2012
Comparative study on the indoor environment quality of green office buildings in China with a long-term field measurement and investigation journal January 2015
The impact of indoor environmental quality on work productivity in university open-plan research offices journal November 2017
A comparison of two direct-reading aerosol monitors with the federal reference method for PM2.5 in indoor air journal January 2002
A New Indoor Environmental Quality Equation for Air-Conditioned Buildings journal March 2005
Influence of indoor environmental quality on the self-estimated performance of office workers in the tropical wet and hot climate of Cameroon journal January 2019
Influence of factors unrelated to environmental quality on occupant satisfaction in LEED and non-LEED certified buildings journal July 2014
The approximation between thermal sensation votes (TSV) and predicted mean vote (PMV): A comparative analysis journal January 2019
An introduction to the Chinese Evaluation Standard for the indoor thermal environment journal October 2014
Post-occupancy evaluation: State-of-the-art analysis and state-of-the-practice review journal April 2018
Thermal comfort and comparison of some parameters coming from hospitals and shopping centers under natural ventilation: The case of Madagascar Island journal September 2017
The Effects of Music, White Noise, and Ambient Noise on Sedation and Anxiety in Patients Under Spinal Anesthesia During Surgery journal October 2014
Changing ventilation rates in U.S. offices: Implications for health, work performance, energy, and associated economics journal January 2012
Quantifying fine particle emission events from time-resolved measurements: Method description and application to 18 California low-income apartments journal October 2017
Occupant productivity and office indoor environment quality: A review of the literature journal August 2016
Indoor Air Pollution and Human Perception in Public Buildings in Tianjin, China journal January 2015
Influence of intensive coronary care acoustics on the quality of care and physiological state of patients journal February 2005
Appraisal of indoor environmental quality (IEQ) in healthcare facilities: A literature review journal September 2015
A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region journal March 2019
Comparison of Short-Term Variations (15-Minute Averages) in Outdoor and Indoor PM 2.5 Concentrations journal July 2000
Combined effects of sound and illuminance on indoor environmental perception journal December 2018
A theoretical adaptive model of thermal comfort – Adaptive Predicted Mean Vote (aPMV) journal October 2009
Indoor air quality in new hotels’ guest rooms of the major world factory region journal March 2009
A thermal comfort model for the non-uniform thermal environments journal August 2018
Evaluation of perceived indoor environmental quality of five-star hotels in China: An application of online review analysis journal January 2017
Development of the adaptive PMV model for improving prediction performances journal July 2015
Continuous monitoring of indoor environmental quality using an Arduino-based data acquisition system journal September 2018