Microphonics Studies at STC in Fermilab
- Michigan State U., East Lansing (main)
- Fermilab
The spoke test cryostat is used to qualify the 325 MHz single spoke resonators at Fermilab (FNAL). During these tests a large detuning on the cavity was observed. The data acquisition for continuous captures were based on measurements from the piezoelectric actuators. A com-parison of the cavity vibrations measured with RF signal from the cavity and piezoelectric actuator signals are shown. The effects of microphonics on the cavity are discussed.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1843239
- Report Number(s):
- FERMILAB-CONF-19-827-TD; oai:inspirehep.net:1840909
- Country of Publication:
- United States
- Language:
- English
Similar Records
Microphonics detuning compensation in 3.9 GHZ superconducting RF cavities
Tests of a tuner for a 325 MHz SRF spoke resonator
Characterization of SSR1 Cavities for PIP-II Linac
Conference
·
Mon Oct 20 00:00:00 EDT 2003
·
OSTI ID:816409
Tests of a tuner for a 325 MHz SRF spoke resonator
Conference
·
Mon Feb 28 23:00:00 EST 2011
·
OSTI ID:1012689
Characterization of SSR1 Cavities for PIP-II Linac
Conference
·
Sat Aug 17 00:00:00 EDT 2019
·
OSTI ID:1843488