CCD camera for dual-energy digital subtraction angiography
Journal Article
·
· IEEE Transactions on Medical Imaging
- Univ. of California, Irvine, CA (United States)
A motion immune dual-energy subtraction technique in which x-ray tube voltage and beam filtration were switched at 30 Hz between 60 kVp (2.0 mm Al filter) and 120 kVp (2.0 mm Al + 2.5 mm Cu filter) was previously reported. In this study, the effects of camera lag on the dual-energy iodine signal is investigated. The temporal lag of the lead oxide vidicon tested reduced the dual-energy iodine signal by a factor of 2.3, as compared to a mode that included 4 scrub frames between low- and high-energy images, for an iodine phantom with thicknesses of 0--86.0 mg/cm{sup 2}, imaged over a 15 cm thick Lucite phantom. On the other hand, the Charge-Coupled Device (CCD) camera has inherently no temporal lag and its versatile scanning characteristics make it near ideal for dual-energy DSA. The CCD camera eliminates the reduction of dual-energy iodine signal, since it does not mix low- and high-energy image data. Another benefit of the CCD camera is that the separation time between low and high-energy images is not limited to the frame period, as is the lead oxide vidicon; and as small as a 5-msec time difference is possible. The short time interval between low and high-energy images minimizes motion misregistration artifacts. Due to these advantages, the CCD camera significantly improves the utility of dual-energy DSA.
- OSTI ID:
- 182944
- Journal Information:
- IEEE Transactions on Medical Imaging, Journal Name: IEEE Transactions on Medical Imaging Journal Issue: 4 Vol. 14; ISSN 0278-0062; ISSN ITMID4
- Country of Publication:
- United States
- Language:
- English
Similar Records
Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification
Quantitative coronary angiography using image recovery techniques for background estimation in unsubtracted images
Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging
Journal Article
·
Thu Jun 15 00:00:00 EDT 2006
· Medical Physics
·
OSTI ID:20853177
Quantitative coronary angiography using image recovery techniques for background estimation in unsubtracted images
Journal Article
·
Mon Oct 15 00:00:00 EDT 2007
· Medical Physics
·
OSTI ID:21032817
Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging
Journal Article
·
Mon Aug 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22689297