Bayesian image reconstruction in SPECT using higher order mechanical models as priors

Journal Article · · IEEE Transactions on Medical Imaging
OSTI ID:182939
;  [1];  [2]
  1. State Univ. of New York, Stony Brook, NY (United States)
  2. Yale Univ., New Haven, CT (United States). Dept. of Computer Science

While the ML-EM (maximum-likelihood-expectation maximization) algorithm for reconstruction for emission tomography is unstable due to the ill-posed nature of the problem, Bayesian reconstruction methods overcome this instability by introducing prior information, often in the form of a spatial smoothness regularizer. More elaborate forms of smoothness constraints may be used to extend the role of the prior beyond that of a stabilizer in order to capture actual spatial information about the object. Previously proposed forms of such prior distributions were based on the assumption of a piecewise constant source distribution. Here, the authors propose an extension to a piecewise linear model--the weak plate--which is more expressive than the piecewise constant model. The weak plate prior not only preserves edges but also allows for piecewise ramplike regions in the reconstruction. Indeed, for the application in SPECT, such ramplike regions are observed in ground-truth source distributions in the form of primate autoradiographs of rCBF radionuclides. To incorporate the weak plate prior in a MAP approach, the authors model the prior as a Gibbs distribution and use a GEM formulation for the optimization. They compare quantitative performance of the ML-EM algorithm, a GEM algorithm with a prior favoring piecewise constant regions, and a GEM algorithm with the weak plate prior. Pointwise and regional bias and variance of ensemble image reconstructions are used as indications of image quality. The results show that the weak plate and membrane priors exhibit improved bias and variance relative to ML-EM techniques.

OSTI ID:
182939
Journal Information:
IEEE Transactions on Medical Imaging, Journal Name: IEEE Transactions on Medical Imaging Journal Issue: 4 Vol. 14; ISSN 0278-0062; ISSN ITMID4
Country of Publication:
United States
Language:
English

Similar Records

The thin plate as a regularizer in Bayesian SPECT reconstruction
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513262

Bayesian reconstruction of functional images using anatomical information as priors
Journal Article · Tue Nov 30 23:00:00 EST 1993 · IEEE Transactions on Medical Imaging (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:5043048

Region of interest evaluation of SPECT image reconstruction methods using a realistic brain phantom
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513249