Corrective Action Decision Document/Closure Report for Corrective Action Unit 406: Area 3 Building 03-74 & Building 03-58 Underground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 & Area 9 Building 09-52 Underground Discharge Points, Tonopah Test Range, Nevada, Revision 0
- International Technologies Corporation, Las Vegas, NV (United States)
This Corrective Action Decision Document/Closure Report (CADD/CR) has been prepared for Corrective Action Unit (CAU) 406: Area 3 Building 03-74 & Building 03-58 Underground Discharge Points (UDPs) and CAU 429: Area 3 Building 03-55 & Area 9 Building 09-52 UDPs. Corrective Action Unit 406 is comprised of the following Corrective Action Sites (CASs): CAS 03-51-002-0374, Heavy Duty Shop (Building 03-74) UDP, Sumps; CAS 03-51-003-0358, Uninterrupted Power Supply (UPS) (Building 03-58) UDP Corrective Action Unit 429 is comprised of the following CASs: CAS 03-51-001-0355, Photo Shop (Building 03-55) UDP, Drains; CAS 09-51-001-0952, Mobile Photographic Lab (Building 09-52) UDPs. The scope of this CADD/CR is to justify and recommend that no corrective action is required at CAUs 406 and 429. To achieve this, the following actions are required: Review the current site conditions, including the concentration and extent of contamination; Document closure of the CAUs.
- Research Organization:
- International Technologies Corporation, Las Vegas, NV (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM)
- DOE Contract Number:
- AC08-97NV13052
- OSTI ID:
- 1818286
- Report Number(s):
- DOE/NV--591
- Country of Publication:
- United States
- Language:
- English
Similar Records
Corrective Action Decision Document for Corrective Action Unit 423: Building 03-60 Underground Discharge Point, Tonopah Test Range, Nevada
Record of Technical Change {number_sign}1 for ''Corrective Action Investigation Plan for Corrective Action Unit 406: Area 3 Building 03-74 and Building 03-58 Underground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 and Area 9 Building 09-52 Underground Discharge Points, Tonopah Test Range, Nevada'' Revision 0
Related Subjects
Corrective Action Decision Document/Closure Report for Corrective Action Unit 406: Area 3 Building 03-74 & Building 03-58
Nevada
Tonopah Test Range
Underground Discharge Points
Underground Discharge Points and Corrective Action Unit 429: Area 3 Building 03-55 & Area 9 Building 09-52