Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Tank Inspection NDE Results for Waste Tanks 25, 26, 33, 34, 41 and 50 (FY2019)

Technical Report ·
DOI:https://doi.org/10.2172/1807897· OSTI ID:1807897
 [1];  [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
In-service inspection is an essential element of a comprehensive structural integrity program for the carbon steel waste tanks at the Savannah River Site. Inspection confirms the effectiveness of corrosion controls used to preclude localized and general corrosion of the tanks. Ultrasonic inspection (UT) is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of an 8.5 inch wide strip extending over the accessible height of the primary tank wall and knuckle regions. selected welds are also inspected for cracking parallel or perpendicular to the weld. The inspections were performed from the annular space of the Type III/IIIA waste storage tanks. The ISI Program calls for thickness mapping and crack detection scans on specified areas of the tank covering all present and historic waste interface levels and selected welds with particular emphasis on the highest stress region of the tank.
Research Organization:
Savannah River Site (SRS), Aiken, SC (United States); Savannah River National Lab (SRNL), Aiken, SC (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM)
DOE Contract Number:
AC09-08SR22470
OSTI ID:
1807897
Report Number(s):
SRNL-STI--2019-00519
Country of Publication:
United States
Language:
English

Similar Records

Tank Inspection NDE Results for Fiscal Year 2014, Waste Tanks 26, 27, 28 and 33
Technical Report · Mon Sep 29 00:00:00 EDT 2014 · OSTI ID:1188369

SRS Type II HLW Tank 15 NDE Inspection Results
Technical Report · Wed Sep 03 00:00:00 EDT 2003 · OSTI ID:817858

TANK INSPECTION NDE RESULTS FOR FISCAL YEAR 2007INCLUDING WASTE TANKS 35, 36, 37, 38 AND 15