Applications of principal component analysis for energy reconstruction in position-sensitive semiconductor detectors

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [2];  [2]
  1. University of Michigan, Ann Arbor, MI (United States); OSTI
  2. University of Michigan, Ann Arbor, MI (United States)
We report semiconductor detectors with pixelated anodes offer a desirable combination of position sensitivity and energy resolution that are suitable for numerous applications in gamma-ray detection and imaging. Pixelization of electrodes also entails a non-uniform amplitude response as a function of gamma-ray interaction position. Energy calibrations as a function of interaction position improve energy resolution, but systematic errors in the energy reconstruction process persist and limit energy resolution at fixed electronic noise. Digitization of signals induced on collecting and adjacent electrodes offers rich information about gamma-ray interactions and their charge drift and collection as a function of time. Despite the abundance of signals for each interaction, human intuition and rule-based approaches fail to utilize the entire set of observed signals to mitigate the sources of systematic error. In order to maximize the utility of digitized signals and improve energy resolution, principal component analysis is applied towards digitized signals observed in semiconductor detectors with pixelated anodes. Principal components identified in the process form the basis for position-specific energy corrections. By leveraging this additional information encoded within digitized signals, energy resolution improves by factors between 10 and 15% with respect to full-width at half and tenth maximum values. The feature that accounts for the maximum amount of explained variance between interactions in any given pixel correlates strongly with the depth of interaction.
Research Organization:
University of Michigan, Ann Arbor, MI (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
NA0002534
OSTI ID:
1801112
Alternate ID(s):
OSTI ID: 1595523
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Issue: C Vol. 954; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (16)

X-ray detectors with digitized preamplifiers journal June 1996
Pixellated CdZnTe detector arrays
  • Doty, F. P.; Barber, H. B.; Augustine, F. L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 353, Issue 1-3 https://doi.org/10.1016/0168-9002(94)91675-6
journal December 1994
Semiconductor arrays with multiplexer readout for gamma-ray imaging: results for a 48 × 48 Ge array
  • Barber, H. B.; Augustine, F. L.; Barrett, H. H.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 353, Issue 1-3 https://doi.org/10.1016/0168-9002(94)91676-4
journal December 1994
Digital signal processing for CdTe detectors based on a waveform clustering algorithm
  • Takahashi, H.; Kurahashi, T.; Zhang, L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 458, Issue 1-2 https://doi.org/10.1016/S0168-9002(00)01038-X
journal February 2001
Review of the Shockley–Ramo theorem and its application in semiconductor gamma-ray detectors journal May 2001
Electrode configuration and energy resolution in gamma-ray detectors journal October 1996
Position-sensitive single carrier CdZnTe detectors
  • He, Z.; Knoll, G. F.; Wehe, D. K.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 388, Issue 1-2 https://doi.org/10.1016/S0168-9002(97)00318-5
journal March 1997
Energy resolution improvement of CdTe detectors by using the principal component analysis technique journal February 2018
Analysis of a complex of statistical variables into principal components. journal January 1933
Estimates of the Regression Coefficient Based on Kendall's Tau journal December 1968
Charge Transport in Arrays of Semiconductor Gamma-Ray Detectors journal July 1995
CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems journal June 2004
Improved resolution for 3-D position sensitive CdZnTe spectrometers journal October 2004
Factors limiting the performance of CdZnTe detectors journal June 2005
3-D position sensitive CdZnTe spectrometer performance using third generation VAS/TAT readout electronics journal September 2005
Sub-Pixel Position Sensing for Pixelated, 3-D Position Sensitive, Wide Band-Gap, Semiconductor, Gamma-Ray Detectors journal June 2011

Similar Records

Semiconductor detectors with proximity signal readout
Technical Report · Sat Apr 14 00:00:00 EDT 2012 · OSTI ID:1120945

System to quantify gamma-ray radial energy deposition in semiconductor detectors
Patent · Sun Dec 31 23:00:00 EST 2000 · OSTI ID:873631

An imaging CdZnTe detector with coplanar orthogonal anode strips
Book · Wed Dec 30 23:00:00 EST 1998 · OSTI ID:323847