skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A new generation of uranium coincidence fast neutron collars for assay of LWR fresh fuel assemblies

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment

The active uranium neutron coincidence collar provides a means of non-destructively assaying the fissile linear density of Light Water Reactor fresh fuel assemblies containing low enriched uranium. These neutron collars can operate in two modes: a thermal and a fast mode. In fast mode, a neutron collar has an added cadmium (Cd) liner in the sample cavity of the detector to reduce the impact of the burnable poison (thermal neutron absorber) on the detector signal (doubles). The main advantage for operating in fast mode is a detected signal that is less dependent of the burnable neutron poison content and thus less dependent on facility operator declarations. The drawback is that operating in fast mode requires a longer measurement time (~hour vs tens of minutes for thermal mode) to achieve the statistically needed precision in the measurements. The trend in the modern reactor fuel assemblies is moving to higher burnup by using higher initial enrichment and, consequently, a higher number of burnable poison rods to compensate the initial neutron reactivity. The increase of the burnable poison loading has motivated the development of a new generation of high efficiency fast neutron collars to allow practical measurements in-field by nuclear inspectors. This paper describes the development and performance evaluation of a new generation of neutron collars, for both boiling water reactor (BWR) and pressurized water reactor (PWR) fuels, jointly developed between the US Department of Energy, through Los Alamos National Laboratory, and the Euratom Safeguards Directorate of the European Commission. In this work, we present here calibrations with reference fuel assemblies at Los Alamos National Laboratory as well as the results of in-field measurement campaigns in fuel fabrication plants with modern commercial fuel assemblies. The experimental results show that a typical PWR verification can be made in a total time of 30 min with an uncertainty in the measured mass of 2% at one standard deviation (1σ). A BWR verification can be made in 47 min with an uncertainty in the measured mass of 1.9% at 1σ, or a total time of 20 min with 1σ uncertainty in the measured mass of 2.5%.

Research Organization:
Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
89233218CNA000001
OSTI ID:
1785482
Report Number(s):
LA-UR-21-20854; TRN: US2210359
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 1009; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (2)

A new fast neutron collar for safeguards inspection measurements of fresh low enriched uranium fuel assemblies containing burnable poison rods
  • Evans, Louise G.; Swinhoe, Martyn T.; Menlove, Howard O.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 729 https://doi.org/10.1016/j.nima.2013.08.028
journal November 2013
Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate
  • Croft, Stephen; Burr, Tom; Favalli, Andrea
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 811 https://doi.org/10.1016/j.nima.2015.11.154
journal March 2016