Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Linker-Free Magnetite-Decorated Gold Nanoparticles (Fe3O4-Au): Synthesis, Characterization, and Application for Electrochemical Detection of Arsenic (III)

Journal Article · · Sensors
DOI:https://doi.org/10.3390/s21030883· OSTI ID:1783351

Linker-free magnetite nanoparticles (Fe3O4NPs)-decorated gold nanoparticles (AuNPs) were grown using a new protocol that can be used as a new platform for synthesis of other intact metal–metal oxide nanocomposites without the need for linkers. This minimizes the distance between the metal and metal oxide nanoparticles and ensures the optimum combined effects between the two material interfaces. X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy confirmed the successful synthesis of the Fe3O4-Au nanocomposite, without any change in the magnetite phase. Characterization, using transmission electron microscopy (TEM), scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy, revealed the composite to consist of AuNPs of 70 ± 10 nm diameter decorated with tiny 10 ± 3 nm diameter Fe3O4NPs in Au:Fe mass ratio of 5:1. The prepared Fe3O4-Au nanocomposite was embedded in ionic liquid (IL) and applied for the modification of glassy carbon electrode (GCE) for the electrochemical detection of As(III) in water. By combining the excellent catalytic properties of the AuNPs with the high adsorption capacity of the tiny Fe3O4NPs towards As(III), as well as the good conductivity of IL, the Fe3O4-Au-IL nanocomposite showed excellent performance in the square wave anodic stripping voltammetry detection of As(III). Under the optimized conditions, a linear range of 1 to 100 μg/L was achieved with a detection limit of 0.22 μg/L (S/N = 3), and no interference from 100-fold higher concentrations of a wide variety of cations and anions found in water. A very low residual standard deviation of 1.16% confirmed the high precision/reproducibility of As(III) analysis and the reliability of the Fe3O4-Au-IL sensing interface. Finally, this proposed sensing interface was successfully applied to analyzing synthetic river and wastewater samples with a 95–101% recovery, demonstrating excellent accuracy, even in complex synthetic river and wastewater samples containing high concentrations of humic acid without any sample pretreatments.

Sponsoring Organization:
USDOE
Grant/Contract Number:
FE0030456
OSTI ID:
1783351
Journal Information:
Sensors, Journal Name: Sensors Journal Issue: 3 Vol. 21; ISSN SENSC9; ISSN 1424-8220
Publisher:
MDPI AGCopyright Statement
Country of Publication:
Switzerland
Language:
English

References (49)

Core-Protected Platinum Monolayer Shell High-Stability Electrocatalysts for Fuel-Cell Cathodes journal October 2010
Heat-Assisted Electrodissolution of Platinum in an Ionic Liquid journal January 2012
Lead Sensor Using Gold Nanostructured Screen-Printed Carbon Electrodes as Transducers journal April 2009
Anodic stripping voltammetric determination of total arsenic using a gold nanoparticle-modified boron-doped diamond electrode on a paper-based device journal June 2018
Nitrogen removal from synthetic wastewater by simultaneous nitrification and denitrification (SND) via nitrite in an intermittently-aerated reactor journal January 1999
Speciation and analysis of mercury, arsenic, and selenium by atomic fluorescence spectrometry journal January 2000
Monitoring arsenic in the environment: a review of science and technologies with the potential for field measurements journal March 2005
Analytical applications of room-temperature ionic liquids: A review of recent efforts journal January 2006
Applications of ionic liquids in electrochemical sensors journal January 2008
Voltammetric methods for determination and speciation of inorganic arsenic in the environment—A review journal July 2009
Simultaneous electrochemical determination of arsenic, copper, lead and mercury in unpolluted fresh waters using a vibrating gold microwire electrode journal October 2011
Electrochemical genosensors for biomedical applications based on gold nanoparticles journal April 2007
Electrochemical determination of inorganic mercury and arsenic—A review journal December 2015
Non-lytic M13 phage-based highly sensitive impedimetric cytosensor for detection of coliforms journal January 2020
Removal of arsenic(V) by magnetic nanoparticle activated microfibrillated cellulose journal January 2015
Electroactive ceramic carbon electrode modified with ionic liquid journal March 2005
Simultaneous multi-channel hydride generation atomic fluorescence spectrometry determination of arsenic, bismuth, tellurium and selenium in tea leaves journal February 2011
Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: Application to potentiometric monitoring of mercury ion(II) journal November 2010
Selective electrochemical sensing for arsenite using rGO/Fe3O4 nanocomposites journal January 2017
Noble metal nanomaterials: Controllable synthesis and application in fuel cells and analytical sensors journal June 2011
Residential exposure to drinking water arsenic in Inner Mongolia, China journal August 2007
ICP-MS for specific detection in capillary electrophoresis journal January 2005
Electrochemical Determination of Arsenite Using a Gold Nanoparticle Modified Glassy Carbon Electrode and Flow Analysis journal December 2005
Green Analyzer for the Measurement of Total Arsenic in Drinking Water: Electrochemical Reduction of Arsenate to Arsine and Gas Phase Chemiluminescence with Ozone journal April 2010
Toward Membrane-Free Amperometric Gas Sensors: A Microelectrode Array Approach journal May 2010
Selective Detection of As(III) at the Au(111)-like Polycrystalline Gold Electrode journal November 2010
On-Site Analysis of Arsenic in Groundwater Using a Microfabricated Gold Ultramicroelectrode Array journal May 2000
Adsorbent Assisted in Situ Electrocatalysis: An Ultra-Sensitive Detection of As(III) in Water at Fe 3 O 4 Nanosphere Densely Decorated with Au Nanoparticles journal December 2015
Surface Fe(II)/Fe(III) Cycle Promoted Ultra-Highly Sensitive Electrochemical Sensing of Arsenic(III) with Dumbbell-Like Au/Fe 3 O 4 Nanoparticles journal February 2018
Electrochemical Investigation of Arsenic Redox Processes on Pyrite journal March 2017
Enhanced Cathodic Preconcentration of As(0) at Au and Pt Electrodes for Anodic Stripping Voltammetry Analysis of As(III) and As(V) journal May 2015
Charge Transfer on the Nanoscale:  Current Status journal July 2003
Toward Membrane-Free Amperometric Gas Sensors: An Ionic Liquid–Nanoparticle Composite Approach journal August 2011
Third-Order Nonlinear Optical Properties of Colloidal Gold Nanorods journal June 2012
Synthesis and Optical Properties of Linker-Free TiO 2 /CdSe Nanorods journal January 2014
Water-Dispersible Magnetite-Reduced Graphene Oxide Composites for Arsenic Removal journal June 2010
Oxidative mechanism of arsenic toxicity and carcinogenesis journal January 2004
Synthesis and evaluation of the SERS effect of Fe 3 O 4 –Ag Janus composite materials for separable, highly sensitive substrates journal January 2019
Gold nano particles catalyzed oxidation of hydrazine by a metallo-superoxide complex: experimental evidences for surface activity of gold nano particles journal January 2012
Invited Reviews: Carcinogenic and Systemic Health Effects Associated with Arsenic Exposure—A Critical Review journal October 2003
Hybrid nanocarrier system for guiding and augmenting simvastatin cytotoxic activity against prostate cancer journal October 2018
Groundwater Arsenic Contamination Throughout China journal August 2013
Synthesis of Silica-Coated Magnetic Nanoparticles and Application in the Detection of Pathogenic Viruses journal January 2013
Preparation of hollow magnetite microspheres and their applications as drugs carriers journal April 2012
Yucca-derived synthesis of gold nanomaterial and their catalytic potential journal January 2014
Electrochemical Detection of As(III) by a rGO/Fe3O4-modified Screen-Printed Carbon Electrode journal January 2016
Adsorptive Stripping Voltammetry of Environmental Carcinogens journal July 2008
Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water journal October 2020
A River about to Die: Yamuna journal January 2010

Similar Records

The Vital Function of Fe3O4@Au nanocomposites for Hydrolase Biosensor Design and Its Application in Detection of Methyl Parathion
Journal Article · Sun Feb 03 23:00:00 EST 2013 · Nanoscale, 5(3):1121-1126 · OSTI ID:1063728

Related Subjects