Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Univ. of Texas, Austin, TX (United States)
- National Nuclear Energy Commission of Brazil (CNEN), Rio de Janeiro (Brazil)
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay235U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE; USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- 89233218CNA000001
- OSTI ID:
- 1773335
- Alternate ID(s):
- OSTI ID: 1829524
- Report Number(s):
- LA-UR--20-29416
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 1001; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Technical basis for the use of a correlated neutron source in the uranium neutron coincidence collar
Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement
Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel
Journal Article
·
Sun Jan 15 19:00:00 EST 2017
· Nuclear Technology
·
OSTI ID:1342866
Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement
Technical Report
·
Sat Dec 31 23:00:00 EST 2016
·
OSTI ID:1339397
Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel
Technical Report
·
Tue Nov 01 00:00:00 EDT 2016
·
OSTI ID:1339396