Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [2];  [2];  [3];  [4]
  1. Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Univ. of Texas, Austin, TX (United States)
  2. National Nuclear Energy Commission of Brazil (CNEN), Rio de Janeiro (Brazil)
  3. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
  4. Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay235U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.
Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE; USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
89233218CNA000001
OSTI ID:
1773335
Alternate ID(s):
OSTI ID: 1829524
Report Number(s):
LA-UR--20-29416
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 1001; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (13)

A fast-neutron coincidence collar using liquid scintillators for fresh fuel verification journal August 2017
The use of neutron intensity calibrated 9Be(α, n) sources as 4438 keV gamma-ray reference standards journal August 1989
Energy spectra of neutrons produced by α-particles in thick targets of light elements journal January 1983
Measurement of the 241Am–Li radionuclide neutron source spectrum journal September 2003
The ideal neutron energy spectrum of 241AmLi(α,n)10B sources journal October 2012
A new fast neutron collar for safeguards inspection measurements of fresh low enriched uranium fuel assemblies containing burnable poison rods
  • Evans, Louise G.; Swinhoe, Martyn T.; Menlove, Howard O.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 729 https://doi.org/10.1016/j.nima.2013.08.028
journal November 2013
The optimum choice of gate width for neutron coincidence counting
  • Croft, S.; Henzlova, D.; Favalli, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 764 https://doi.org/10.1016/j.nima.2014.06.083
journal November 2014
Point model equations for neutron correlation counting: Extension of Böhnel׳s equations to any order
  • Favalli, Andrea; Croft, Stephen; Santi, Peter
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 795 https://doi.org/10.1016/j.nima.2015.06.009
journal September 2015
Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate
  • Croft, Stephen; Burr, Tom; Favalli, Andrea
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 811 https://doi.org/10.1016/j.nima.2015.11.154
journal March 2016
Variations in AmLi source spectra and their estimation utilizing the 5 Ring Multiplicity Counter
  • Weinmann-Smith, R.; Beddingfield, D. H.; Enqvist, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 856 https://doi.org/10.1016/j.nima.2017.02.083
journal June 2017
Applications of Bonner Sphere Detectors in Neutron Field Dosimetry journal January 1985
Measurement and Monte Carlo modelling of the JRC 241Am-Li( ,n) source spectrum journal August 2004
The Spectrum of Neutrons from A 238Pu-Li Source journal January 1981

Similar Records

Technical basis for the use of a correlated neutron source in the uranium neutron coincidence collar
Journal Article · Sun Jan 15 19:00:00 EST 2017 · Nuclear Technology · OSTI ID:1342866

Boron-Coated Straw Collar for Uranium Neutron Coincidence Collar Replacement
Technical Report · Sat Dec 31 23:00:00 EST 2016 · OSTI ID:1339397

Simulations of a PSD Plastic Neutron Collar for Assaying Fresh Fuel
Technical Report · Tue Nov 01 00:00:00 EDT 2016 · OSTI ID:1339396