Preliminary - Specification High Temperature Chloride Molten Salt Vertical Turbine Pump

Technical Report ·
DOI:https://doi.org/10.2172/1762385· OSTI ID:1762385
 [1];  [2]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
  2. Bridgers and Paxton, Albuquerque, NM (United States)

This specification provides to the supplier with requirements for design, manufacturing, inspection and testing in works and cleaning, painting, packing and protection for transport to site for the hot molten salt pumps, receiver circulation pumps and the attemperation molten salt pumps to be used at Sandia National Laboratories, Albuquerque, NM, NSTTF Solar Power Tower.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bridgers and Paxton, Albuquerque, NM (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Renewable Power Office. Solar Energy Technologies Office; USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1762385
Report Number(s):
SAND--2019-5135R; 675334
Country of Publication:
United States
Language:
English

Similar Records

Operation of large-scale pumps and valves in molten salt
Journal Article · Mon Aug 01 00:00:00 EDT 1994 · Journal of Solar Energy Engineering; (United States) · OSTI ID:6954573

Molten fuel-salt reactor
Patent · Tue Aug 30 00:00:00 EDT 1977 · OSTI ID:7209048

An interim report on testing the molten salt pump and valve loops
Technical Report · Sat Mar 31 23:00:00 EST 1990 · OSTI ID:7030230

Related Subjects