Validation of MCNPX-PoliMi code for simulations of radioxenon beta–gamma coincidence detection
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Univ. of Michigan, Ann Arbor, MI (United States)
- Politecnico di Milano, Milan (Italy)
- Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Radioxenon detection is an important component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty. We developed and validated a new model in MCNPX-PoliMi to simulate the decay of various radioxenon isotopes and the detector response of a variety of detector types. The model was validated using calibration data from a plastic and NaI(Tl) beta–gamma coincidence detector and the results are presented. Furthermore, the results of this validation show that this model can also be used as a tool to produce training spectra and as a method to calibrate radioxenon detection systems.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- NA0002534; AC05-76RL01830
- OSTI ID:
- 1464492
- Alternate ID(s):
- OSTI ID: 1703443
OSTI ID: 1523812
- Report Number(s):
- PNNL-SA--135096; PII: S0168900218309380
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Issue: C Vol. 906; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Validation of MCNPX-PoliMi code for simulations of radioxenon beta-gamma coincidence detection
Gain Calibration of a Beta/Gamma Coincidence Spectrometer for Automated Radioxenon Analysis
Characterization of PIPS detectors for measurement of radioxenon
Journal Article
·
Sun Oct 21 00:00:00 EDT 2018
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1523812
Gain Calibration of a Beta/Gamma Coincidence Spectrometer for Automated Radioxenon Analysis
Journal Article
·
Wed Mar 31 23:00:00 EST 2004
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, 521(2-3):586-599
·
OSTI ID:15010566
Characterization of PIPS detectors for measurement of radioxenon
Journal Article
·
Mon Aug 29 00:00:00 EDT 2022
· Journal of Radioanalytical and Nuclear Chemistry
·
OSTI ID:1878547