Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate
- Building Science Corporation, Westford, MA (United States)
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.
- Research Organization:
- National Renewable Energy Laboratory (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- Contributing Organization:
- Dupont Shelter Solutions; North American Insulation Manufacturers Association; Owens Corning; Nu-Wool; Dorken Systems Inc.
- DOE Contract Number:
- AC36-08GO28308; EE0007570
- OSTI ID:
- 1677422
- Report Number(s):
- NREL/TP--5500-77518; DOE/GO--102020-5450; MainId:27454; UUID:4b5913c5-3fb2-4c0b-b347-e3bf2f430d42; MainAdminID:18509
- Country of Publication:
- United States
- Language:
- English
Similar Records
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting
Dataset
·
Wed Apr 27 00:00:00 EDT 2016
·
OSTI ID:2204220
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
Technical Report
·
Sun Jan 31 23:00:00 EST 2016
·
OSTI ID:1239735
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting
Technical Report
·
Thu Feb 04 23:00:00 EST 2016
·
OSTI ID:1238328