Ultimate Bifacial Showdown: 75kW Field Results
This work presents one year results for a side-by-side comparison of 5 different bifacial technologies, deployed in a 75-kW single-axis tracked field at Golden, CO. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed for a direct technology comparison and calculation of bifacial gain. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. High accuracy string-level DC monitoring and module-level measurements are also presented, showing effects of snow and edge effects in the order of +/- 3% for non-uniform irradiance across the row. Data from a custom-module to measure shading loss from the torque-tube is installed, showing up to 6% irradiance non-uniformity for the month of January.
- Research Organization:
- National Renewable Energy Laboratory (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Solar Energy Technologies Office (EE-4S)
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1669536
- Report Number(s):
- NREL/PR-5K00-77486; MainId:27422; UUID:4e50a053-20dc-4740-959f-7f8fa0f305b4; MainAdminID:16256
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measuring and Modeling Bifacial Technologies
Model and Validation of Single-Axis Tracking with Bifacial PV