Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Development of an intense negative hydrogen ion source with an external magnetic filter

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1145655· OSTI ID:165061
; ; ; ; ; ; ; ;  [1];  [2];  [3]
  1. National Institute for Fusion Science, Nagoya 464-01 (Japan)
  2. Hitachi Research Laboratory, Hitachi Ltd., Hitachi 316 (Japan)
  3. Kokubu Works, Hitachi Ltd., Hitachi 316 (Japan)
An intense negative hydrogen ion source has been developed, which has a strong external magnetic filter field in the wide area of 35 cm{times}62 cm produced by a pair of permanent magnet rows located at 35.4 cm separation. The filter strength is 70 G in the center and the line-integrated filter strength is 850 G cm, which keeps the low electron temperature in the extraction region. Strong cusp magnetic field, 1.8 kG on the chamber surface, is generated for improvement of the plasma confinement. These resulted in the high arc efficiency at the low operational gas pressure. 16.2 A of H{sup {minus}} ion current with the energy of 47 keV was obtained at the arc efficiency of 0.1 A/kW at the gas pressure of 3.8 mTorr in the cesium-mode operation. The magnetic field in the extraction gap is also strong, 450 G, for the electron suppression. The ratio of the extraction current to the negative ion current was less than 2.2 at the gas pressure of 3 mTorr. The two-stage acceleration was tested, and 13.6 A of H{sup {minus}} ion beam was accelerated to 125 keV. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.
OSTI ID:
165061
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 3 Vol. 66; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

High-energy and high-current hydrogen negative-ion beam production with an external-filter-type large negative-ion source
Journal Article · Thu Feb 29 23:00:00 EST 1996 · Review of Scientific Instruments · OSTI ID:279231

Comparison of H sup minus and D sup minus production in a magnetically filtered multicusp source
Conference · Sun Dec 31 23:00:00 EST 1989 · Review of Scientific Instruments; (USA) · OSTI ID:6993002

Development of large scale negative ion source for LHD-NBI
Journal Article · Thu Aug 20 00:00:00 EDT 1998 · AIP Conference Proceedings · OSTI ID:21199182