US manufacturing industry fails to recover an estimated 900 trillion BTUs of low-temperature waste heat from its processes each year. A grand research challenge has been to develop waste heat recovery technology that can be applied to industrial manufacturing processes and vehicle operations. The Oak Ridge National Laboratory (ORNL)/Eaton research team performed computational research and development to design an innovative direct-contact heat exchanger (DCHE) technology to deliver low-cost, compact, longer-lifetime, high-efficiency waste heat recovery that is optimized for a low-temperature organic Rankine cycle. ORNL resources and expertise in high performance computing (HPC) and multiphase flows were utilized to realize this goal while advancing the fundamental understanding of two-phase, two-immiscible-fluid turbulent flow heat transfer for heat exchangers. In the first stage of the project, a computational fluid dynamics (CFD) model of a DCHE was developed. Verification and limited validation of the numerical solution were performed using experimental data from published literature. To support efforts in verification and validation, two-dimensional CFD models were also developed with the objective of investigating different boundary conditions to reach converged, steady-state solutions.Based on benchmarking efforts, a baseline industry-grade design of a DCHE was developed, which consists of two horizontal pipes of different cross-sectional areas – joined by a converging-diverging nozzle in the middle and relies on a three-phase system with co-current flows for operation. Evaporation of the cold liquid (n-pentane or methanol) by the hot liquid water occurs in the first pipe. The first pipe contains two inlets for liquid water and liquid pentane (or liquid methanol). The second pipe with the larger cross-sectional area serves as a gravity-driven phase-separator. It contains two outlets that are staggered to avoid entrainment of the liquid water phase by the gas phase. This baseline design resulted from several trial-and-error evaluations using two-dimensional CFD models. Confirmatory three-dimensional CFD models were also run for different mass flow rates and inlet temperatures (inlet water temperature ranging from 50°C to 90°C), and efficiency plots were produced to fully characterize the proposed industrial-grade design of the DCHE.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1649390
Report Number(s):
ORNL/TM-2019/1455; CRADA/NFE-18-07223
Country of Publication:
United States
Language:
English

Similar Records

Sensitivity Analysis of Passive Heat Removal Capability of FHR Based on Efficient Surrogate Model and GenFlow
Journal Article · Fri Jul 01 00:00:00 EDT 2016 · Transactions of the American Nuclear Society · OSTI ID:1649390

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P
Technical Report · Wed Jul 01 00:00:00 EDT 2020 · OSTI ID:1649390

Demonstration of An Integrated Approach to Mercury Control at Lee Station
Technical Report · Mon Dec 31 00:00:00 EST 2007 · OSTI ID:1649390

Related Subjects