Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Optimization of Dual Axis Asymmetric Cavity for Energy Recovery Linac

Conference ·
OSTI ID:1647166
 [1];  [1];  [1];  [2];  [3];  [4]
  1. MEPhI, Moscow, Russia
  2. JAI, Oxford, United Kingdom
  3. Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
  4. SLAC National Accelerator Lab., Menlo Park, CA (United States)
Optimization of the dual axis asymmetric cavity was performed to minimize the ratio of the peak magnetic and electric fields values to the accelerating voltage, to increase the distance between operating and neighbouring modes as well as to reduce the manufacturing cost of the cavity. To reach the goals several solutions have been suggested bringing the ratios to the acceptable values and leading to simplification of the manufacturing of the structure.
Research Organization:
Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Nuclear Physics (NP)
DOE Contract Number:
AC05-06OR23177
OSTI ID:
1647166
Report Number(s):
JLAB-ACC-18-2901; DOE/OR/23177-5026
Country of Publication:
United States
Language:
English

Similar Records

Experimental studies of 7-cell dual axis asymmetric cavity for energy recovery linac
Journal Article · Mon Oct 09 20:00:00 EDT 2017 · Physical Review Accelerators and Beams · OSTI ID:1407121

Dual-axis energy recovery linac.
Conference · Sun Dec 31 23:00:00 EST 2006 · OSTI ID:972999

Conceptual design considerations of a 5-cell dual-axis SRF cavity for ERLs.
Conference · Sun Dec 31 23:00:00 EST 2006 · OSTI ID:973474