Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Design and implementation of the new scintillation light detection system of ICARUS T600

Journal Article · · Journal of Instrumentation
ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.
Research Organization:
Brookhaven National Laboratory (BNL), Upton, NY (United States); Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
Contributing Organization:
ICARUS Collaboration
Grant/Contract Number:
AC02-07CH11359
OSTI ID:
1647074
Alternate ID(s):
OSTI ID: 23037117
Report Number(s):
FERMILAB-PUB--20-230-ND; arXiv:2006.05261; oai:inspirehep.net:1800472
Journal Information:
Journal of Instrumentation, Journal Name: Journal of Instrumentation Journal Issue: 10 Vol. 15; ISSN 1748-0221
Publisher:
Institute of Physics (IOP)Copyright Statement
Country of Publication:
United States
Language:
English

References (22)

Comparison between large area photo-multiplier tubes at cryogenic temperature for neutrino and rare event physics experiments
  • Falcone, A.; Bertoni, R.; Boffelli, F.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 787 https://doi.org/10.1016/j.nima.2014.11.017
journal July 2015
A laser diode based system for calibration of fast time-of-flight detectors journal May 2016
Performance of large area PMTs at cryogenic temperatures for neutrino and rare event physics experiments
  • Falcone, Andrea; Boffelli, Fabrizio; Bonesini, Maurizio
  • Proceedings of International Conference on New Photo-detectors — PoS(PhotoDet2015) https://doi.org/10.22323/1.252.0019
conference June 2016
The trigger system of the ICARUS experiment for the CNGS beam text January 2014
The laser diode calibration system of the ICARUS T600 detector at FNAL text January 2020
Absolute calibration and monitoring of a spectrometric channel using a photomultiplier
  • Bellamy, E. H.; Bellettini, G.; Budagov, J.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 339, Issue 3 https://doi.org/10.1016/0168-9002(94)90183-X
journal February 1994
Detection of the VUV liquid argon scintillation light by means of glass-window photomultiplier tubes
  • Benetti, P.; Montanari, C.; Raselli, G. L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 505, Issue 1-2 https://doi.org/10.1016/S0168-9002(03)01027-1
journal June 2003
Design, construction and tests of the ICARUS T600 detector
  • Amerio, S.; Amoruso, S.; Antonello, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 527, Issue 3 https://doi.org/10.1016/j.nima.2004.02.044
journal July 2004
Characterization of ETL 9357FLA photomultiplier tubes for cryogenic temperature applications
  • Ankowski, A.; Antonello, M.; Aprili, P.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 556, Issue 1 https://doi.org/10.1016/j.nima.2005.10.108
journal January 2006
Linearity and saturation properties of Hamamatsu R5912-MOD photomultiplier tube for the ICARUS T600 light detection system
  • Babicz, Marta; Bellini, Vincenzo; Bonesini, Maurizio
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 936 https://doi.org/10.1016/j.nima.2018.10.113
journal August 2019
A particle detector that exploits Liquid Argon scintillation light
  • Babicz, M.; Diwan, M.; Fava, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 958 https://doi.org/10.1016/j.nima.2019.162421
journal April 2020
Performance study of the new light collection system for the ICARUS T600 detector journal September 2017
Developing scintillation light readout simulation for the SBND experiment journal January 2016
A laser diode based system for calibration of fast time-of-flight detectors journal May 2016
Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector journal October 2018
New read-out electronics for ICARUS-T600 liquid argon TPC. Description, simulation and tests of the new front-end and ADC system journal December 2018
An innovative technique for TPB deposition on convex window photomultiplier tubes journal December 2018
The laser diode calibration system of the ICARUS T600 detector at FNAL journal May 2020
A measurement of the group velocity of scintillation light in liquid argon journal September 2020
Characterization of large area PMTs at cryogenic temperature for rare event physics experiments journal March 2014
The trigger system of the ICARUS experiment for the CNGS beam journal August 2014
Precise 3D Track Reconstruction Algorithm for the ICARUS T600 Liquid Argon Time Projection Chamber Detector journal January 2013