Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Fluorescent lamp discharge models -- Critical issues

Conference ·
OSTI ID:163175
 [1]
  1. Osram Sylvania Inc., Danvers, MA (United States)
This talk is a review of several fluorescent lamp positive column models available to the authors. They briefly describe the underlying physics associated with each model. The models are then applied to standard fluorescent lamp conditions where good agreement between models and experimental data is shown. However, for conditions applicable to small diameter fluorescent lamps, serious disagreement between the various models was encountered. In addition, problems with numerical convergence become more severe under these conditions. Included is an analysis of the numerical techniques used in these models, and a comparison with earlier positive column models. Suggestions are made for changes in the numerical algorithms to improve the numerical robustness. To bring better agreement between model and experimental results for narrow diameter fluorescent lamps required some additional physics that were ignored in all the models surveyed.
OSTI ID:
163175
Report Number(s):
CONF-950612--; ISBN 0-7803-2669-5
Country of Publication:
United States
Language:
English

Similar Records

Modeling of highly loaded fluorescent lamps
Conference · Thu Jul 01 00:00:00 EDT 1999 · OSTI ID:20050653

Compact fluorescent lamps
Journal Article · Thu Jul 01 00:00:00 EDT 1982 · J. Illum. Eng. Soc.; (United States) · OSTI ID:6670878

Numerical study on xenon positive column discharges of mercury-free lamp
Journal Article · Wed Feb 14 23:00:00 EST 2007 · Journal of Applied Physics · OSTI ID:20982698