Subcritical Measurements for Calculational Verification of HEU Tube Vault Storage at the Oak Ridge Y-12 Plant

Conference ·
OSTI ID:162496
 [1];  [1];  [1]
  1. Oak Ridge Y-12 Plant (Y-12), Oak Ridge, TN (United States)

252Cf-source-driven frequency analysis measurements have been performed for a highly enriched uranium ({approximately}93.2) metal storage vault at the Oak Ridge Y-12 Plant to provide data for verification of a calculational method for criticality safety and to assess the effects of any loss of unbound water from the concrete. The measurements showed that a 3 X 3 X 10 array of 18.75-kg uranium annular castings is essentially infinite since the results for the 5 X 5 X 10 array are not statistically different from those of the smaller array. These measured frequency analysis parameters are presented.

Research Organization:
Oak Ridge Y-12 Plant (Y-12), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
162496
Report Number(s):
Y/DD--689; CONF-9509100--39; ON: DE96003499
Country of Publication:
United States
Language:
English