The electron cyclotron emission (ECE) diagnostic on the experimental advanced superconducting tokamak (EAST) was upgraded recently to provide electron temperature profile measurement with wider radial coverage and better precision. Here, the lower limit of the ECE detection frequency band was extended from 104 GHz to 97 GHz by adding a new 8-channel heterodyne radiometer, which ensures capability for the measurement of the second harmonic ECE with toroidal magnetic field down to 1.75 T. Also, the existing 32-channel heterodyne radiometer has been upgraded, with the frequency interval for the lower frequency range up to 120 GHz reduced from 2 GHz to 1 GHz by introducing eight channels in the intermediate frequency part. In addition, a plan is presented to incorporate tunable yttrium iron garnet filters into the existing heterodyne radiometer to obtain detailed measurements of the electron temperature gradient scale length as well as finer spatial pinpointing of magnetohydrodynamic modes. Examples from DIII-D are provided where similar ECE diagnostic allowed precise measurement of the center and width of neoclassical tearing modes.
- Research Organization:
- General Atomics, San Diego, CA (United States); Univ. of Texas, Austin, TX (United States)
- Sponsoring Organization:
- National Magnetic Confinement Fusion Science Program of China; USDOE Office of Science (SC)
- Grant/Contract Number:
- FC02-04ER54698; FG02-97ER54415; SC0010500
- OSTI ID:
- 1609203
- Alternate ID(s):
- OSTI ID: 1467530
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 89; ISSN 0034-6748
- Publisher:
- American Institute of Physics (AIP)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Characteristics of off-axis sawteeth with an internal transport barrier in EAST
|
journal | July 2019 |
Similar Records
An upgraded 32-channel heterodyne electron cyclotron emission radiometer on Tore Supra
Progress in ITER ECE diagnostic design and integration
ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK
Journal Article
·
Wed Dec 14 23:00:00 EST 2005
· Review of Scientific Instruments
·
OSTI ID:20778485
Progress in ITER ECE diagnostic design and integration
Journal Article
·
Tue Apr 19 20:00:00 EDT 2022
· Journal of Instrumentation
·
OSTI ID:1869954
ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK
Conference
·
Thu Aug 01 00:00:00 EDT 2002
·
OSTI ID:813649