COMET/ZEUS Activation Foils Report for Irradiations IER-241 and IER-261
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
The goal of this work was to determine the internal neutron spectrum of the COMET/ZEUS assembly using activation foils. Similar measurements were performed on the COMET assembly when it was located at the Los Alamos Critical Experiments Facility (LACEF) at the Los Alamos National Laboratory (LANL). The present measurements were performed after the COMET assembly was moved to the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). The December 2012 COMET/ZEUS irradiation was the first in a series of experiments, and the COMET/ZEUS assembly was selected because of operational readiness and authorization to run specific targets. The August 2013 irradiation was the second in the series and involved only small changes in the configuration. This report describes the unfolding of the activation foils to determine the internal neutron spectra.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- DOE Contract Number:
- 89233218CNA000001
- OSTI ID:
- 1607908
- Report Number(s):
- LA-UR--20-22545
- Country of Publication:
- United States
- Language:
- English