Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Double exponential approximation and inverse double exponential fit for Bell Labs and International-Military Standard EMP waveforms

Technical Report ·
DOI:https://doi.org/10.2172/1602134· OSTI ID:1602134
 [1];  [1]
  1. Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)

We summarize here the double exponential and inverse double exponential approximations for two common EMP waveforms, the Bell Laboratories (Bell Labs) and the International- military standard (IEC-MIL-STD). Both models have been used frequently due to their relatively easy analytical expressions for both the time domain waveforms and their associated frequency domain spectra.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1602134
Report Number(s):
SAND--2020-1883; 684209
Country of Publication:
United States
Language:
English

Similar Records

Engineering evaluation and analysis for the improvement of military standard generators. Volume 2. Final report, 24 February-29 May 1987
Technical Report · Fri May 29 00:00:00 EDT 1987 · OSTI ID:6708782

An investigation of the validity of applying MIL-STD-285 to EMP shielding effectiveness. Final report, 1 October 1976--15 April 1977
Technical Report · Thu Apr 14 23:00:00 EST 1977 · OSTI ID:6589454

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP
Journal Article · Mon Jul 17 00:00:00 EDT 2023 · IEEE Transactions on Industry Applications · OSTI ID:2204588