Title: Comparison of gas analyzers for eddy covariance: Effects of analyzer type and spectral corrections on fluxes

Journal Article · · Agricultural and Forest Meteorology
 [1];  [1]; ORCiD logo [2];  [3];  [4];  [5];  [6];  [6]; ORCiD logo [1]
  1. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
  2. Univ. of Nebraska, Lincoln, NE (United States)
  3. LI-COR Biosciences, Lincoln, NE (United States); Univ. of Nebraska, Lincoln, NE (United States)
  4. LI-COR Biosciences, Lincoln, NE (United States)
  5. Picarro Inc., Santa Clara, CA (United States)
  6. Campbell Scientific, Logan, UT (United States)

The eddy covariance technique (EC) is used at hundreds of field sites worldwide to measure trace gas exchange between the surface and the atmosphere. Data quality and correction methods for EC have been studied empirically and theoretically for many years. The recent development of new gas analyzers has led to an increase in technological options for users. Open-path (no inlet tube) and closed-path (long inlet tube) sensors have been used for a long time, whereas enclosed-path (short inlet tube) sensors are relatively new. In this work, we tested the comparability of fluxes calculated from five different gas analyzers including two open-path (LI-7500 A from LI-COR, IRGASON from Campbell), two enclosed-path (CPEC200 from Campbell, LI-7200 from LI-COR), and one closed-path (2311-f; from Picarro) analyzers, which were all located on a single tower at an irrigated alfalfa field in Davis, CA. To effectively compare sensors with different tube characteristics we used three different spectral correction methods. We found that all sensors, regardless of type, can be used to measure fluxes if appropriate corrections are applied and quality control measures are taken. However, the comparability strongly depended on the gas (CO2 or H2O) and the correction method. Average differences were below 4% for CO2 fluxes using any spectral correction method, but for H2O average differences were between 4% and 13% for the different methods. The magnitude of corrections also varied strongly, especially for water vapor fluxes. This study does not identify the best sensor, but rather weighs the benefits and difficulties of each sensor and sensor type. Our findings show that enclosed and closed-path gas analyzers that measure water vapor with inlet tubes experience large high frequency attenuation and should be corrected with empirical correction methods. This information presented here about different the diverse sensors be considered by investigators when choosing a sensor for a site or when analyzing EC measurements from multiple sites.

Research Organization:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Biological and Environmental Research (BER)
Grant/Contract Number:
AC02-05CH11231
OSTI ID:
1580842
Journal Information:
Agricultural and Forest Meteorology, Vol. 272-273, Issue C; ISSN 0168-1923
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 7 works
Citation information provided by
Web of Science

References (57)

FLUXNET: A New Tool to Study the Temporal and Spatial Variability of Ecosystem–Scale Carbon Dioxide, Water Vapor, and Energy Flux Densities journal November 2001
A Portable Eddy Covariance System for the Measurement of Ecosystem–Atmosphere Exchange of CO 2 , Water Vapor, and Energy journal April 2004
Effects of the Gill-Solent WindMaster-Pro “w-boost” firmware bug on eddy covariance fluxes and some simple recovery strategies journal February 2019
Addressing the influence of instrument surface heat exchange on the measurements of CO 2 flux from open-path gas analyzers journal August 2008
Calculating CO2 and H2O eddy covariance fluxes from an enclosed gas analyzer using an instantaneous mixing ratio journal September 2011
Failure of Taylor's hypothesis in the atmospheric surface layer and its correction for eddy-covariance measurements: Correction of Taylor's Hypothesis journal May 2017
Improved trace gas flux estimation through IRGA sampling optimization journal March 2009
A cavity ring-down analyzer for measuring atmospheric levels of methane, carbon dioxide, and water vapor journal August 2008
New Transfer Functions for Correcting Turbulent Water Vapour Fluxes journal July 2010
Flow distortion by supporting structures journal March 1981
Sampling error in eddy correlation flux measurements journal February 2001
A Re-Evaluation of Long-Term Flux Measurement Techniques Part I: Averaging and Coordinate Rotation journal April 2003
Underestimates of sensible heat flux due to vertical velocity measurement errors in non-orthogonal sonic anemometers journal April 2013
All Sonic Anemometers Need to Correct for Transducer and Structural Shadowing in Their Velocity Measurements* journal January 2016
Relative humidity effects on water vapour fluxes measured with closed-path eddy-covariance systems with short sampling lines journal November 2012
The Influence of Wind Direction on Campbell Scientific CSAT3 and Gill R3-50 Sonic Anemometer Measurements journal November 2016
Open-path vs. closed-path eddy covariance measurements of the net ecosystem carbon dioxide and water vapour exchange: A long-term perspective journal February 2009
Addressing a systematic bias in carbon dioxide flux measurements with the EC150 and the IRGASON open-path gas analyzers journal November 2016
A Simple Formula for Attenuation of eddy Fluxes Measured with First-Order-Response Scalar Sensors journal February 1997
On Frequency Response Corrections for Eddy Covariance Flux Measurements journal March 2000
Attenuation of Scalar Fluxes Measured with Spatially-displaced Sensors journal January 2009
Correction of a Non-orthogonal, Three-Component Sonic Anemometer for Flow Distortion by Transducer Shadowing journal February 2015
Measurements of Flow Distortion within the IRGASON Integrated Sonic Anemometer and CO $$_2$$ 2 /H $$_2$$ 2 O Gas Analyzer journal February 2016
Evaluation of Probe-Induced Flow Distortion of Campbell CSAT3 Sonic Anemometers by Numerical Simulation journal June 2017
Strong low-pass filtering effects on water vapour flux measurements with closed-path eddy correlation systems journal December 2007
On the use of the Webb–Pearman–Leuning theory for closed-path eddy correlation measurements journal January 2007
Spectral characteristics of surface-layer turbulence journal July 1972
Relating eddy correlation sensible heat flux to horizontal sensor separation in the unstable atmospheric surface layer journal January 1994
The attenuation of fluctuations in scalar concentrations through sampling tubes journal January 1991
The relative merits of open- and closed-path analysers for measurement of eddy fluxes journal June 1996
Comparison of eddy-covariance measurements of CO2 fluxes by open- and closed-path CO2 analysers journal May 1992
Eddy-covariance CO2 flux measurements using open- and closed-path CO2 analysers: Corrections for analyser water vapour sensitivity and damping of fluctuations in air sampling tubes journal October 1990
An eddy-covariance system with an innovative vortex intake for measuring carbon dioxide and water fluxes of ecosystems journal January 2017
Relative Humidity Effect on the High-Frequency Attenuation of Water Vapor Flux Measured by a Closed-Path Eddy Covariance System journal September 2009
A simple method for estimating frequency response corrections for eddy covariance systems journal August 2000
Reply to comment by Rannik on “A simple method for estimating frequency response corrections for eddy covariance systems” journal April 2001
Attenuation of concentration fluctuations of water vapor and other trace gases in turbulent tube flow journal January 2008
Impact of post-field data processing on eddy covariance flux estimates and energy balance closure [Impact of post-field data processing on eddy covariance flux estimates and energy balance closure] journal December 2006
Field intercomparison of prevailing sonic anemometers journal January 2018
Optimization of an enclosed gas analyzer sampling system for measuring eddy covariance fluxes of H 2 O and CO 2 journal January 2016
A system to measure surface fluxes of momentum, sensible heat, water vapour and carbon dioxide journal February 1997
Frequency response corrections for eddy correlation systems journal October 1986
Ultrasonic anemometer angle of attack errors under turbulent conditions journal September 2012
Correction of sonic anemometer angle of attack errors journal January 2006
Importance of mixing ratio for a long-term CO 2 flux measurement with a closed-path system journal January 2011
A Wavelet-Based Correction Method for Eddy-Covariance High-Frequency Losses in Scalar Concentration Measurements journal August 2012
Eddy covariance measurements with a new fast-response, enclosed-path analyzer: Spectral characteristics and cross-system comparisons journal November 2013
Attenuation Correction Procedures for Water Vapour Fluxes from Closed-Path Eddy-Covariance Systems journal January 2012
Scalar Similarity for Relaxed Eddy Accumulation Methods journal July 2006
Empirical assessment of uncertainties of meteorological parameters and turbulent fluxes in the AmeriFlux network: UNCERTAINTIES IN THE AMERIFLUX NETWORK journal December 2012
Spectral Characteristics and Correction of Long-Term Eddy-Covariance Measurements Over Two Mixed Hardwood Forests in Non-Flat Terrain journal February 2004
Influences of various calculation options on heat, water and carbon fluxes determined by open- and closed-path eddy covariance methods journal January 2012
A Meta-Analysis of Open-Path Eddy Covariance Observations of Apparent CO2 Flux in Cold Conditions in FLUXNET journal November 2017
Correction of flux measurements for density effects due to heat and water vapour transfer journal January 1980
The Effects of Probe-Induced Flow Distortion on Atmospheric Turbulence Measurements journal July 1981
Flow-distortion effects on scalar flux measurements in the surface layer: Implications for sensor design journal January 1988
Pressure correction to the long-term measurement of carbon dioxide flux journal January 2011

Cited By (1)

Low-cost eddy covariance: a case study of evapotranspiration over agroforestry in Germany journal January 2019