Luminaire dirt depreciation (LDD): Field data from several exterior lighting projects
Journal Article
·
· LEUKOS - The Journal of the Illuminating Engineering Society of North America
- BATTELLE (PACIFIC NW LAB)
Luminaire dirt depreciation (LDD) data were evaluated for seven luminaires from three different project sites in Philadelphia PA, Minneapolis MN, and Yuma AZ. In each case, the luminaires were removed from the installation, carefully packaged and transported to a photometric testing laboratory, and then tested in the “as-is” or dirty condition, cleaned, and re-tested. In terms of light output, the results showed that the IES RP-36-15 method for estimating LDD was applicable to the LED luminaires evaluated. General claims of lower levels of dirt deprecation (or higher LDD values) for LED luminaires than for luminaires using conventional light sources were not supported by the test data for the LED luminaires in these three projects. While the overall measured lumen depreciation due to accumulated dirt closely matched IES estimates for LDD, the data indicated that the accumulated dirt on the luminaires dramatically altered the luminous intensity distribution of the luminaires, with reductions in intensity of more than 25% at peak angles. These effects on luminous intensity distribution are not accounted for in IES LDD estimates.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 1578144
- Report Number(s):
- PNNL-SA-130333
- Journal Information:
- LEUKOS - The Journal of the Illuminating Engineering Society of North America, Journal Name: LEUKOS - The Journal of the Illuminating Engineering Society of North America Journal Issue: 1 Vol. 15
- Country of Publication:
- United States
- Language:
- English
Luminaire Dirt Depreciation for an Indirect Lighting System
|
journal | January 2005 |
Zero-Distance In-Place Indoor Luminaire Flux Measurements
|
journal | July 1996 |
Maintenance and Adjustment Factors in Street Lighting Design Calculations
|
journal | October 1971 |
Illuminance Uniformity of Outdoor Sports Lighting
|
journal | April 2011 |
Similar Records
Lighting energy management in industrial plants
Yuma Border Patrol Area Lighting Retrofit LED System Performance in a Trial Installation – Two Years Later
Software to evaluate lighting maintenance: Other ways to save energy
Conference
·
Tue Jun 01 00:00:00 EDT 1982
· Energy Technol. (Wash., D.C.); (United States)
·
OSTI ID:5561687
Yuma Border Patrol Area Lighting Retrofit LED System Performance in a Trial Installation – Two Years Later
Technical Report
·
Sat May 21 00:00:00 EDT 2016
·
OSTI ID:1349989
Software to evaluate lighting maintenance: Other ways to save energy
Journal Article
·
Fri Dec 31 23:00:00 EST 1993
· Energy Engineering; (United States)
·
OSTI ID:6902624