The M8 Power Calibration Experiment (M8CAL)

Technical Report ·
DOI:https://doi.org/10.2172/1576492· OSTI ID:1576492
 [1];  [1]
  1. Argonne National Lab. (ANL), Argonne, IL (United States)

The M8 calibration experiment was a series of 23 irradiations in TREAT performed to determine the relationship between the fission power generated in the TREAT core and the fission power generated in experiment fuel located in an in-core experiment vehicle and irradiated by core neutrons. The experiment was planned to provide the essential calibration information specifically needed for planning and analysis of the M8 test (and subsequent tests similar in geometry to M8) to be performed in the post-upgrade TREAT core. Irradiations were performed in TREAT cores loaded with a full-slotted (to optimize hodoscope performance) and with a half-slotted (to maximize energy deposition). Tests included a few selected low-power irradiations of fresh IFR-type U-Zr and U-Pu-Zr fuel pins supplemented by multiple irradiations of uranium-zirconium monitor wires ranging from low steady-state power to high-power maximal transients. This report describes the M8CAL test hardware, measurements, analysis assumptions, and methods used to deduce power coupling between the reactor and experiment fuel—including both absolute magnitudes and axial distributions. Power coupling results are reported for fresh IFR fuel pins under high-power transient test conditions appropriate to the planned M8 transient test. In line with previous calibration data, measured dependence of power coupling on the specifics of each irradiation is also shown to correlate well with the in-core axial locations of the TREAT control rods. Estimates are made for maximal test fuel energy deposition capability in controlled transients.

Research Organization:
Argonne National Laboratory (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC02-06CH11357
OSTI ID:
1576492
Report Number(s):
ANL-IFR--232; 154294
Country of Publication:
United States
Language:
English

Similar Records

The M8 Power Calibration Experiment (M8CAL)
Technical Report · Sun May 01 00:00:00 EDT 1994 · OSTI ID:1130413

The MB Power Calibration Experiment (M8CAL)
Technical Report · Sun May 01 00:00:00 EDT 1994 · OSTI ID:10200159

M8 power calibration (M8CAL) hodoscope report
Technical Report · Sat Oct 01 00:00:00 EDT 1994 · OSTI ID:10200318