Mitigation of persistent current effects in the RHIC superconducting magnets
Persistent currents in superconducting magnet introduce magnetic errors especially at low operating fields. In addition, their decay causes magnetic field variations and therefore drifts of the beam orbits, tunes and chromaticities. To reduce field errors and suppress magnetic field variations, a new magnetic cycle was proposed for the low-energy beam operation at the Relativistic Heavy Ion Collider (RHIC). In the new magnetic cycle, the magnet current oscillates around the nominal operating current with diminishing amplitude a few times before it settles. The new magnetic cycle has been demonstrated experimentally to reduce field errors and the amplitude of magnetic field variations significantly and is essential for the ongoing RHIC BeamEnergy Scan II (BES-II) program. This article will present beam-based experimental studies of the persistent current effects with the new magnetic cycle, and discuss its application in RHIC.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States); Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP)
- Grant/Contract Number:
- AC02-05CH11231; SC0012704
- OSTI ID:
- 1575835
- Alternate ID(s):
- OSTI ID: 1574430; OSTI ID: 1604714
- Report Number(s):
- BNL-212344-2019-JAAM; PRABCJ; 111003
- Journal Information:
- Physical Review Accelerators and Beams, Journal Name: Physical Review Accelerators and Beams Vol. 22 Journal Issue: 11; ISSN 2469-9888
- Publisher:
- American Physical Society (APS)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Web of Science
Similar Records
Gold-gold luminosity increase in RHIC for a beam energy scan with colliding beam energies extending below the nominal injection energy
BEAM-BASED MEASUREMENTS OF PERSISTENT CURRENT DECAY IN RHIC.