skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Water Ingress Testing of Commercially Available Containers for the TA-55 Criticality Safety Program

Technical Report ·
DOI:https://doi.org/10.2172/1558028· OSTI ID:1558028

This memorandum outlines the water ingress test results for several commercially available container types that are advertised as “leak tight” but need to be tested to the water resistant criteria set forth by the TA-55 Criticality Safety Program. The usage of SAVY-4000 containers as water resistant containers inside gloveboxes, although allowed, is expensive, ergonomically challenging, and could be avoided if there is a commercial alternative that meets the water ingress criterion. The contents of this document are strictly for TA55 Criticality Safety Requirements (PA-RD01009), and it is not to be used to assign a damage ratio for the reduction of material at risk or implementation in the documented safety analysis. The NMCC will proceed as identified under PA-DOP-0091, and will be invoked as the review and approval control regarding usage of these containers in the facility.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
89233218CNA000001
OSTI ID:
1558028
Report Number(s):
LA-UR-19-28268
Country of Publication:
United States
Language:
English