Optimization of the size and shape of the scanning aperture in autocollimator-based deflectometric profilometers

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.5058710· OSTI ID:1542362
 [1];  [2];  [2];  [3];  [4];  [5];  [1];  [1]
  1. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
  2. Physikalisch-Technische Bundesanstalt (Germany)
  3. Helmholtz Zentrum Berlin für Materialien und Energie, Berlin (Germany)
  4. Leibniz Inst. of Surface Engineering (IOM (Germany); Technische Universitaet Dresden (Germany)
  5. Leibniz Inst. of Surface Engineering (IOM (Germany)
Deflectometric profilometers based on industrial electronic autocollimators (ACs), as the ELCOMAT-3000, have become indispensable tools for precision form measurements of optical surfaces. A growing number of labs at synchrotron and free electron laser x-ray facilities are going for BESSY-II NOM-like versions of the AC-based profilometers. These tools have proven capable of characterizing state-of-the-art aspherical x-ray optics with an accuracy on the level of 100 nrad (root-mean-square) over the spatial frequency range limited by the size of the aperture used in the profilometer. Normally, a round aperture with a diameter of about 2.5 mm is used. Previous investigations have shown that with the optimally aligned 2.5-mm aperture, the spatial resolution of a NOM-like profilometer corresponding to the first zero-crossing of the optical transform function (OTF) is ~1.2 mm. In this paper, we investigate the performance of an AC ELCOMAT-3000 for a slope profilometer with different aperture sizes and shapes. The results of angular calibration of the AC equipped with circular and rectangular apertures placed at different distances from the AC are discussed. The calibration was performed at the Physikalisch-Technische Bundesanstalt using the original experimental arrangements, also discussed in the paper. The OTF measurements with the specially developed test sample with chirped surface slope profiles were performed at the Advanced Light Source X-Ray Optics Laboratory (XROL) in application to a new optical surface measuring system under development at the XROL. In the OTF measurements, we have shown that application of a rectangular aperture with dimensions of 1.5 mm × 3 mm improves the spatial resolution in the tangential direction by a factor of ~1.4 compared to that of the standard circular aperture of 2.5-mm diameter. We postulate that the conclusions of our investigations are crucial for reaching fundamental metrological limits in deflectometric profilometry utilizing state-of-the-art electronic autocollimators.
Research Organization:
Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
Grant/Contract Number:
AC02-05CH11231
OSTI ID:
1542362
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 2 Vol. 90; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
English

References (36)

The Diamond-NOM: A non-contact profiler capable of characterizing optical figure error with sub-nanometre repeatability
  • Alcock, S. G.; Sawhney, K. J. S.; Scott, S.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 616, Issue 2-3 https://doi.org/10.1016/j.nima.2009.10.137
journal May 2010
Sub-microradian surface slope metrology with the ALS Developmental Long Trace Profiler
  • Yashchuk, Valeriy V.; Barber, Samuel; Domning, Edward E.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 616, Issue 2-3 https://doi.org/10.1016/j.nima.2009.10.175
journal May 2010
Autocollimators for deflectometry: Current status and future progress
  • Geckeler, Ralf D.; Just, Andreas; Krause, Michael
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 616, Issue 2-3 https://doi.org/10.1016/j.nima.2009.11.021
journal May 2010
Characterization and calibration of 2nd generation slope measuring profiler
  • Siewert, Frank; Buchheim, Jana; Zeschke, Thomas
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 616, Issue 2-3 https://doi.org/10.1016/j.nima.2009.12.033
journal May 2010
Sub-nm accuracy metrology for ultra-precise reflective X-ray optics
  • Siewert, F.; Buchheim, J.; Zeschke, T.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 635, Issue 1 https://doi.org/10.1016/j.nima.2010.10.137
journal April 2011
Characterization of the error budget of Alba-NOM
  • Nicolas, Josep; Martínez, Juan Carlos
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 710 https://doi.org/10.1016/j.nima.2012.10.125
journal May 2013
Investigations on the spatial resolution of autocollimator-based slope measuring profilers
  • Siewert, F.; Buchheim, J.; Höft, T.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 710 https://doi.org/10.1016/j.nima.2012.10.130
journal May 2013
Development of a high-performance gantry system for a new generation of optical slope measuring profilers
  • Assoufid, Lahsen; Brown, Nathan; Crews, Dan
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 710 https://doi.org/10.1016/j.nima.2012.11.063
journal May 2013
Stripe pattern in the intensity profile of collimated soft x-ray beams caused by surface corrugation of the refocusing mirrors
  • Schmitz, D.; Siewert, F.; Zeschke, T.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 774 https://doi.org/10.1016/j.nima.2014.11.094
journal February 2015
Approaching sub-50 nanoradian measurements by reducing the saw-tooth deviation of the autocollimator in the Nano-Optic-Measuring Machine
  • Qian, Shinan; Geckeler, Ralf D.; Just, Andreas
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 785 https://doi.org/10.1016/j.nima.2015.02.065
journal June 2015
Comparison of angle standards with the aid of a high-resolution angle encoder journal October 2009
The Nanometer Optical Component Measuring Machine: a new Sub-nm Topography Measuring Device for X-ray Optics at BESSY
  • Siewert, Frank
  • SYNCHROTRON RADIATION INSTRUMENTATION: Eighth International Conference on Synchrotron Radiation Instrumentation, AIP Conference Proceedings https://doi.org/10.1063/1.1757928
conference January 2004
New Products For Synchrotron Application Based On Novel Surface Processing Developments
  • Seifert, Andreas
  • SYNCHROTRON RADIATION INSTRUMENTATION: Ninth International Conference on Synchrotron Radiation Instrumentation, AIP Conference Proceedings https://doi.org/10.1063/1.2436098
conference January 2007
Optimal measurement strategies for effective suppression of drift errors journal November 2009
Aperture alignment in autocollimator-based deflectometric profilometers journal May 2016
Linear chirped slope profile for spatial calibration in slope measuring deflectometry journal May 2016
Calibration of high-resolution electronic autocollimators against an angle comparator journal September 2003
A shearing-based method for the simultaneous calibration of angle measuring devices journal September 2014
Capabilities and limitations of the self-calibration of angle encoders journal March 2014
The new PTB angle comparator journal July 1998
Time-dependent wave front propagation simulation of a hard x-ray split-and-delay unit: Towards a measurement of the temporal coherence properties of x-ray free electron lasers journal November 2014
On the characterization of ultra-precise X-ray optical components: advances and challenges in ex situ metrology journal August 2014
Developmental long-trace profiler using optimally aligned mirror-based pentaprism journal May 2011
Optimal alignment of mirror-based pentaprisms for scanning deflectometric devices journal July 2011
Reliable before-fabrication forecasting of expected surface slope distributions for x-ray optics journal April 2012
Advanced environmental control as a key component in the development of ultrahigh accuracy ex situ metrology for x-ray optics journal October 2015
The developmental long trace profiler (DLTP) optimized for metrology of side-facing optics at the ALS conference September 2014
A new x-ray optics laboratory (XROL) at the ALS: mission, arrangement, metrology capabilities, performance, and future plans conference September 2014
Modeling surface topography of state-of-the-art x-ray mirrors as a result of stochastic polishing process: recent developments conference September 2016
Innovative nano-accuracy surface profiler for sub-50 nrad rms mirror test
  • Qian, Shinan; Idir, Mourad
  • Eighth International Symposium on Advanced Optical Manufacturing and Testing Technology (AOMATT2016), SPIE Proceedings https://doi.org/10.1117/12.2247575
conference October 2016
New twist in the optical schematic of surface slope measuring long trace profiler conference September 2017
Correlation methods in optical metrology with state-of-the-art x-ray mirrors
  • Yashchuk, Valeriy V.; Centers, Gary; Gevorkyan, Gevork S.
  • Correlation Optics 2017, Thirteenth International Conference on Correlation Optics https://doi.org/10.1117/12.2305441
conference January 2018
The ALS OSMS: Optical Surface Measuring System for high accuracy two-dimensional slope metrology with state-of-the-art x-ray mirrors conference November 2018
Air convection noise of pencil-beam interferometer for long trace profiler conference August 2006
Optimized use and calibration of autocollimators in deflectometry conference September 2007
Distance-dependent influences on angle metrology with autocollimators in deflectometry conference August 2008

Cited By (2)

The 6th International Workshop on X-ray Optics and Metrology—IWXM 2018 journal February 2019
Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors conference October 2019

Similar Records

Aperture alignment in autocollimator-based deflectometric profilometers
Journal Article · Sun May 15 00:00:00 EDT 2016 · Review of Scientific Instruments · OSTI ID:22597927

Aperture alignment in autocollimator-based deflectometric profilometers
Journal Article · Mon May 23 20:00:00 EDT 2016 · Review of Scientific Instruments · OSTI ID:1530235

Investigation on lateral resolution of surface slope profilers
Journal Article · Sun Sep 08 20:00:00 EDT 2019 · Proceedings of SPIE - The International Society for Optical Engineering · OSTI ID:1608216