Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Characterization of Gamma-Ray Imagers Using GADRAS

Technical Report ·
DOI:https://doi.org/10.2172/1528842· OSTI ID:1528842
 [1];  [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). WMD CT & Response and WMD Detect & Threat Analysis

This document describes how gamma-ray imagers are characterized using the Gamma Detector Response and Analysis Software (GADRAS). The initial step of the characterization process entails definition of detector dimensions and estimation of a few parameters that are specific to gamma-ray imagers. Energy calibration and resolution parameters are then adjusted based on comparison between computed spectra and measurements for several calibration source. These steps are analogous to the way non-imaging spectrometers are characterized. The parameters are then refined by an empirical process to achieved good agreement between measured and computed spectra as functions of gamma-ray energy and angular group.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation (NA-20)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1528842
Report Number(s):
SAND--2018-5749; 664031
Country of Publication:
United States
Language:
English

Similar Records

Empirical Refinement of the GADRAS Detector Response Function
Technical Report · Mon Apr 01 00:00:00 EDT 2019 · OSTI ID:1762297

GADRAS-DRF Version 18 User's Manual
Technical Report · Sat Nov 30 23:00:00 EST 2019 · OSTI ID:1592910

GADRAS-DRF 18.6 User's Manual
Technical Report · Sun May 01 00:00:00 EDT 2016 · OSTI ID:1431293