Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Modeling Crystalline Silicotitanate Performance to Support TCCR Batch 1 and Batch 1A Operations (U)

Technical Report ·
DOI:https://doi.org/10.2172/1510931· OSTI ID:1510931
 [1]
  1. Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
The objective of this work is to calculate the expected ion-exchange (IX) column performances of the Tank Closure Cesium Removal (TCCR) system for Tank 10H closure. Savannah River National Laboratory (SRNL) utilized: (1) the ZAM computer program (Version 4) developed by Texas A&M University for prediction of cesium loading on the crystalline silicotitanate (CST) media, (2) the OLI Studio™ software (Version 9.6) from OLI Systems to estimate waste solution properties, and (3) the VERSE-LC code (Version 7.8) developed by Purdue University to calculate column performances. The study specifically evaluates the TCCR system performance to process Tank 10H Batch 1A supernate.
Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE Office of Environmental Management (EM)
DOE Contract Number:
AC09-08SR22470
OSTI ID:
1510931
Report Number(s):
SRNL-STI--2019-00147
Country of Publication:
United States
Language:
English