The tracking requirement of the SNS Fast Injection Bump power supplies is described. In addition to the usual tracking between the load current and the input reference of a power supply, these power supplies must also track between pairs of units under slightly different loads. This paper describes the use of a current-null test to measure tracking performances. For the actual tests, a single dummy magnet load was used to measure the tracking between the first two production units at the manufacturer's facility. Using the Yokogawa WE7000 waveform. PC-based measurement instrument, input and output waveforms are digitized and stored in data files. A program written for this application is then used to extract data from these files to construct, analyze the waveforms and characterize the power supply performance. Results of the measurements of two SNS Fast Injection Bump power supplies will be presented in this paper.

Research Organization:
BROOKHAVEN NATIONAL LABORATORY (US)
Sponsoring Organization:
DOE/OFFICE OF SCIENCE (US)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
15007972
Report Number(s):
BNL-71979-2004-CP; R&D Project: 86485; 39KC0200; TRN: US0402922
Resource Relation:
Conference: 9TH EUROPEAN PARTICLE ACCELERATOR CONFERENCE, LUCERNE (CH), 07/05/2004--07/09/2004; Other Information: PBD: 5 Jul 2004