In the Relativistic Heavy Ion Collider (RHIC) the abort kicker magnets are the limiting aperture. Continuous losses at this location could deteriorate the kicker performance. In addition, losses especially in the triplet area cause backgrounds in the experimental detectors. The RHIC one-stage collimation system was used to reduce these backgrounds as well as losses at the abort kickers. Collimation performance and results from various runs with even and uneven species (Au-Au, pp and d-Au) are presented and compared. Upgrades of the system for the upcoming high luminosity runs are outlined.

Research Organization:
BROOKHAVEN NATIONAL LABORATORY (US)
Sponsoring Organization:
DOE/SC (US)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
15006624
Report Number(s):
BNL-71285-2003-CP; R&D Project: AD003; KB0202011; TRN: US0400874
Resource Relation:
Conference: HALO 2003 AND BEAM BEAM WORKSHOP, MONTAUK, NY (US), 06/19/2003--06/23/2003; Other Information: PBD: 19 May 2003