Measurement of Actinides in Environmental Samples at Micro-Becquerel Levels by Accelerator Mass Spectrometry
Conference
·
OSTI ID:15002018
The need for ultra-sensitive actinide measurements continues to expand in the fields of environmental stewardship, nuclear isotope forensics, radiobioassay and environmental research. We have developed a heavy isotope accelerator mass spectrometry (AMS) system at Lawrence Livermore National Laboratory's Center for Accelerator Mass Spectrometry (CAMS). The system was designed particularly for the measurement of actinide concentrations and isotopic ratios. A fast isotope switching capability has been incorporated in the system, allowing flexibility in isotope selection and for the quasi-continuous normalization to a reference isotope spike. Initially, our utilization of the system has concentrated on the measurement of Pu isotopes. Under current operating conditions, background levels equivalent to <10{sup 6} atoms are observed during routine {sup 239}Pu and {sup 240}Pu measurements. Measurements of samples containing 10{sup 13} {sup 238}U atoms demonstrate that the system provides a {sup 238}U rejection factor of >10{sup 7}. Recently, we have utilized the high dynamic range of the AMS system in measuring samples whose Pu contents ranged from <10{sup 6} (background) to >10{sup 11} Pu atoms. Measurements of known materials, combined with results from an externally organized intercomparison program, indicate that our {sup 239}Pu measurements are accurate and precise down to the {mu}Bq level ({approx}10{sup 6} atoms). The development of the heavy isotope system was undertaken with particular interest in the measurement of environmental samples, including soils, sediments, waters, air filters, tissue samples, and human urine. The high rejection of interferences, including molecular interferences, and low susceptibility to matrix components, provided by the AMS technique are of particular relevance for such complex samples. These two factors significantly reduce demands on sample preparation chemistry for Pu analyses, allowing relatively simple, cost-effective procedures to be employed. The sensitivity of the AMS technique indicated by our Pu measurements suggests that the further optimization of sample preparation procedures will allow sample size reductions. When such sample preparation improvements are combined with the high sample throughput capabilities of our AMS system, the result will be a rapid and cost-effective measurement technique for actinides in environmental samples.
- Research Organization:
- Lawrence Livermore National Lab., CA (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 15002018
- Report Number(s):
- UCRL-JC-147861
- Country of Publication:
- United States
- Language:
- English
Similar Records
Actinide Measurements by Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory
DEVELOPMENTS IN THE MEASUREMENT OF ACTINIDES AND129I AT LLNL BY ACCELERATOR MASS SPECTROMETRY
Plutonium measurements by accelerator mass spectrometry at LLNL
Conference
·
Thu Sep 25 00:00:00 EDT 2003
·
OSTI ID:15005875
DEVELOPMENTS IN THE MEASUREMENT OF ACTINIDES AND129I AT LLNL BY ACCELERATOR MASS SPECTROMETRY
Conference
·
Wed Jan 12 23:00:00 EST 2005
·
OSTI ID:15014496
Plutonium measurements by accelerator mass spectrometry at LLNL
Conference
·
Tue Oct 26 00:00:00 EDT 1999
·
OSTI ID:757321