Title: Neutron detection in a high-gamma field using solution-grown stilbene

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [1];  [1];  [1];  [2];  [2]
  1. Univ. of Michigan, Ann Arbor, MI (United States)
  2. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

We present that a solution-based technique for growing large-volume stilbene scintillators was developed in 2013; crystals up to diameters of 10 cm, or larger, have been grown while preserving excellent pulse shape discrimination (PSD) properties. The goal of this study is to evaluate the PSD capabilities of 5.08 by 5.08-cm stilbene crystals grown by Lawrence Livermore National Laboratory and Inrad Optics when exposed to a 1000 to 1 gamma ray-neutron ratio and operating at a 100-kHz count rate. Results were compared to an equivalent EJ-309 liquid scintillation detector. 252Cf neutron pulses were recorded in two experiments where 60Co and 137Cs sources created the high-gamma field. The high count rate created numerous double pulses that were cleaned using fractional and template approaches designed to remove double pulses while preserving neutron counts. PSD was performed at a threshold of 42 keVee (440-keV proton) for stilbene and 60 keVee (610-keV proton) for EJ-309 liquid. The lower threshold in stilbene resulted in a neutron intrinsic efficiency of approximately 14.5%, 10% higher than EJ-309 liquid, for bare 252Cf and 13% for 252Cf in the high-gamma field. Despite the lower threshold, the gamma misclassification rate in stilbene was approximately 3×10$$-$$6, nearly a factor-of-five lower than what we found with the EJ-309 liquid.

Research Organization:
Univ. of Michigan, Ann Arbor, MI (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
Grant/Contract Number:
NA0002534
OSTI ID:
1487036
Alternate ID(s):
OSTI ID: 1397529
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 806, Issue C; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 38 works
Citation information provided by
Web of Science

References (6)

Development of organic scintillators journal June 1979
Pulse-height distributions of neutron and gamma rays from plutonium-oxide samples
  • Pozzi, S. A.; Clarke, S. D.; Flaska, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 608, Issue 2 https://doi.org/10.1016/j.nima.2009.07.007
journal September 2009
The Stilbene Scintillation Crystal as a Spectrometer for Continuous Fast‐Neutron Spectra journal October 1960
The effect of material purity on the optical and scintillation properties of solution-grown trans-stilbene crystals journal April 2013
Scintillation properties of solution-grown trans-stilbene single crystals
  • Zaitseva, Natalia; Glenn, Andrew; Carman, Leslie
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 789 https://doi.org/10.1016/j.nima.2015.03.090
journal July 2015
EJ-309 pulse shape discrimination performance with a high gamma-ray-to-neutron ratio and low threshold
  • Kaplan, A. C.; Flaska, M.; Enqvist, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 729 https://doi.org/10.1016/j.nima.2013.07.081
journal November 2013

Cited By (6)

Simulation of the Nondestructive Assay of 237 Np Using Active Neutron Multiplicity Counting journal September 2019
Testing of Scintillation Detectors in Quasi-Monoenergetic Neutron Spectra in a Silicon Filtered Neutron Beam at the LVR-15 Research Reactor journal May 2019
Characterization of the scintillation anisotropy in crystalline stilbene scintillator detectors journal July 2017
Methane Hydrate: Killer cause of Earth's greatest mass extinction journal December 2016
On the Feynman-alpha Method for Reflected Fissile Assemblies preprint January 2020
Fast Rossi-alpha Measurements of Plutonium using Organic Scintillators text January 2020

Similar Records

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems
Conference · Wed Dec 01 00:00:00 EST 2021 · Transactions of the American Nuclear Society · OSTI ID:1487036

High-precision characterization of the neutron light output of stilbene along the directions of maximum and minimum response
Journal Article · Tue May 21 00:00:00 EDT 2019 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1487036

Cross-correlation measurements with the EJ-299-33 plastic scintillator
Journal Article · Fri Oct 31 00:00:00 EDT 2014 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1487036