Beam Optics Measurements in Medium Energy Beam Transport at PIP-II Injector Test Facility
- Fermilab
- Bhabha Atomic Res. Ctr.
The Proton Improvement Plan-II Injector Test (PIP2IT) is an accelerator test facility under construction at Fermilab that will provide a platform to demonstrate critical technologies and concept of the front-end of the PIP-II linear accelerator (linac). The PIP2IT warm front-end comprises a H⁻ ion source capable of delivering 15 mA, 30 keV DC or pulsed beam, a Low Energy Beam Transport (LEBT), a 162.5 MHz, CW Radio Frequency Quadrupole (RFQ) that accelerates the beam to 2.1 MeV and, a 14 m medium energy beam transport (MEBT). Presently, beamline up to the MEBT has been commissioned and operates routinely at the PIP2IT facility. In this paper, we discuss beam measurements performed at the MEBT to analyze beam emittance and its RMS sizes along the MEBT. In addition, beam based calibration of the beamline elements using differential trajectory measurement is also presented.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP)
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1478027
- Report Number(s):
- FERMILAB-CONF-18-453-TD; 1690658
- Resource Relation:
- Conference: 9th International Particle Accelerator Conference, Vancouver, BC Canada, 04/29-05/04/2018
- Country of Publication:
- United States
- Language:
- English
Similar Records
Design of PIP-II Medium Energy Beam Transport
Experimental Study of Beam Dynamics in the PIP-II MEBT Prototype